Original Research

JOURNAL OF ENDOUROLOGY Volume XX, Number XX, XXXX 2014 ª Mary Ann Liebert, Inc. Pp. ---–--DOI: 10.1089/end.2014.0509

Successful Introduction of Laparoendoscopic Single-Site Donor Nephrectomy After Experience with Laparoscopic Single-Site Plus-One Trocar Donor Nephrectomy Takamitsu Inoue, MD,1 Norihiko Tsuchiya, MD,1 Shintaro Narita, MD,1 Hiroshi Tsuruta, MD,1 Susumu Akihama, MD,1 Mitsuru Saito, MD,1 Shigeru Satoh, MD,1,2 and Tomonori Habuchi, MD1

Abstract

Purpose: To assess the feasibility, safety, and efficacy of the laparoendoscopic single-site (LESS) donor nephrectomy (LESSDN) procedure after experience with the LESS-plus-one-trocar donor nephrectomy (LEPODN) procedure. Patients and Methods: From 2009 to 2014, 126 left laparoscopic donor nephrectomies (LDNs) were performed, including 59 Standard (Std)-LDN, 30 LEPODN, and 37 LESSDN. In the LEPODN procedure, a 5-mm trocar was added as a right-hand working trocar to the LESSDN procedure. A GelPOINT platform was applied on a pararectal single incision in both LEPODN and LESSDN procedures. After performing the LEPODN procedure several times, each surgeon performed the LESSDN procedure. Results: Std-LDN, LEPODN, and LESSDN procedures were performed by 10, 10, and 7 surgeons, respectively. The mean operative time, estimated blood loss, warm ischemia time, time to ambulation, and length of postoperative hospital stay were the shortest for the LESSDN procedure (P < 0.012, P = 0.007, P < 0.001, P = 0.027, and P = 0.001, respectively). No significant difference in the complication rate, delayed graft function rate, and mean 7-day post-transplant serum creatinine levels was observed among the three procedures. Individual results of the operative time and estimated blood loss for the LESSDN procedure were not significantly inferior to those of Std-LDN and LEPODN procedures for each surgeon. Conclusions: The LESSDN procedure can be introduced safely and effectively without compromising the operative time, complication rate, and graft function after experience with the LEPODN procedure among multiple surgeons. The LEPODN procedure may be an effective bridge from standard multiport LDN to LESSDN. miliar angles.6 These difficulties may substantially inhibit the dissemination of the LESS donor nephrectomy (LESSDN) procedure in which minimal complications and morbidity as well as excellent allograft function is mandatory.7 Previous studies have shown the technical feasibility and safety of LESSDN.8–18 The reports of initial experiences have indicated the need for flexible instruments.8–11 Recent reports, however, have not indicated similar requirements.12,13,15–18 To replace the use of flexible instruments, the recent LESSDN procedures need a GelPort or GelPOINT (Applied Medical, Rancho Santa Margarita, CA) platform on a single incision that is made at the beginning of the procedure. This platform on a single incision of approximately 5–6 cm can provide sufficient instrumental triangulation to complete the

Introduction

A

s surgical experience in laparoscopic procedures has increased in the last two decades, laparoscopic donor nephrectomy (LDN) has become recognized as a standard procedure.1 Laparoendoscopic single-site (LESS) surgery, performed through a single incision, has been used recently in various patients needing urologic surgical procedures at several institutes.2–4 Lower morbidity rates and better cosmetic outcomes with the LESS procedure make it an attractive option for potential kidney transplant donors.5 The LESS procedure, however, usually needs specialized curved or flexible articulating instruments that are awkward in shape, inhibit maneuverability, and require the surgeon to work at unfa-

1 Department of Urology and 2Center for Kidney Disease and Transplantation, Akita University Graduate School of Medicine, Akita, Japan.

1

2

procedure without using flexible instruments. The LESSDN procedure, however, has been performed by only a few surgeons even at high-volume centers. This indicates that LESSDN is still considered to be a challenging procedure to be safely taught to multiple surgeons, even without the need for flexible instruments.15–17 Previous reports of the LESSDN procedure have alerted that it should be performed only by experienced surgeons who are comfortable with the Standard (Std)-LDN procedure.11,18 To facilitate the LESS procedure, we previously reported successful experience with LESS-plus-one-trocar living donor nephrectomy (LEPODN).19 In brief, the GelPort platform was placed on a pararectal skin incision of approximately 5–6 cm, and a 5-mm trocar was inserted under the costal arch to provide a broader trocar triangulation. The technique for the LEPODN procedure has been successfully shared among eight urologic surgeons at our institution and may be an effective technical bridge to safely introduce the LESSDN procedure among multiple surgeons.

INOUE ET AL.

In this study, we assessed the feasibility, safety, and efficacy of the left LESSDN procedure after the experience with the left LEPODN procedure of multiple surgeons who were already comfortable with standard laparoscopic procedures. Once each surgeon performed the LEPODN procedure several times as the main surgeon, each performed the LESSDN procedure using the GelPOINT platform on a pararectal single incision without the use of flexible instruments with the guidance of the senior surgeons. The outcome of the LESSDN procedure after the LEPODN procedure was assessed and compared with that of the Std-LDN and LEPODN procedures. Patients and Methods

From June 2007 to June 2014, 126 donors underwent the left LDN procedure at the Akita University Medical Center, Japan. Four right LDN and two right LEPODN procedures performed during the same period were excluded from this study because it was necessary to insert an additional trocar to

FIG. 1. (A) Abdominal wound diagram of LEPODN: (a) an approximately 5–6-cm pararectal incision and (b) a 5-mm right-hand working trocar wound. (B) Trocars and the GelPOINT (or GelPort) configuration of LEPODN: (c) an additional 5-mm right-hand working trocar under the costal arch, (d) a GelPOINT (or GelPort) loading scheme on the pararectal incision, (e) a 10-mm camera trocar, (f) a 10-mm left-hand trocar, (g) an opening in the gel for the Endo-TATM 30 stapler and ENDO CATCHTM II pouch, and (h) a 10-mm assistant trocar. (C) Abdominal wound diagram of LESSDN: (i) an approximately 5–6-cm pararectal incision. (D) Trocars and a GelPOINT configuration of LESSDN: (j) a GelPOINT loading scheme on the pararectal incision, (k) a 10-mm right-hand trocar, (l) a 10-mm assistant trocar, (m) a 10-mm lefthand trocar, (n) the opening in the gel for the Endo-TA 30 stapler and ENDO CATCH II pouch, and (o) a 10-mm camera trocar.

LESS AFTER LESS-PLUS-ONE DONOR NEPHRECTOMY

3

retract the liver. Fifty-nine Std-LDN procedures were performed from October 2007 to October 2010, and 30 LEPODN procedures and 37 LESSDN procedures were performed from November 2010 to June 2014. All the surgeons who participated in this study had enough experience with standard laparoscopic radical nephrectomy but no experience with any LESS procedure using flexible instruments. Surgeons already comfortable with the Std-LDN procedure were allowed to perform the LEPODN procedures several times; subsequently, each surgeon performed the LESSDN procedure under the guidance of senior surgeons. Informed consent was obtained from all donors before the procedure. Donor eligibility at our institution has been described previously.20–22 The study protocols regarding Std-LDN, LEPODN, and LESSDN procedures were approved by the Akita University Medical Center Institutional Review Board. Several perioperative clinical factors were compared among the three procedures, including the operative time (min), estimated blood loss (mL), warm ischemia time (WIT) of the graft kidney (sec), time to oral intake (days), time to ambulation (days), length of postoperative hospital stay (days), occurrence of delayed graft function (DGF), and serum creatinine levels (mg/mL) of the donors and recipients. DGF was defined as the requirement for dialysis therapy within 7 days after renal transplantation. Results of the operative time and estimated blood loss of the three procedures were individually assessed for each surgeon. Postoperative surgical complications were assessed using the Clavien– Dindo classification system.23 The donors were placed in the right lateral decubitus position during the procedures. All intraperitoneal procedures were essentially similar because all three procedures involved only the use of straight instruments. The renal artery and vein were stapled and divided using a Multifire EndoTATM 30 stapler (Covidien, Boulder, CO) and scissors. The details of our intraperitoneal procedures have been described previously.19

(Fig. 1A). The three ports of the GelPOINT system were inserted in the gel cap (Fig. 1B). A rigid 10-mm 30-degree digital laparoscope with a 90-degree light adapter was also used. A 5-mm right-hand trocar was inserted under the costal arch at least 5-cm lateral to the edge of the GelPOINT (Fig. 1B, Fig. 2A). The Multifire Endo-TA 30 stapler and the ENDO CATCH II pouch were directly inserted through the opening in the gel that was manually created on the GelPOINT platform (Fig. 1B). The Multifire Endo-TA 30 stapler was inserted through the 12-mm left-hand trocar during the process of using the GelPort platform. A 19F diameter drain was intraperitoneally placed using a 5-mm right-hand trocar. The LESSDN procedure

The GelPOINT platform was placed on the pararectal incision (Fig. 1C). The four ports of the GelPOINT system were inserted in the gel cap (Fig. 1D, Fig. 2B). A rigid 30-degree long digital laparoscope (5 mm in diameter and 50 cm in length) or a standard rigid 10-mm 30-degree digital laparoscope with a 90-degree light adapter were selected, depending on the procedure conditions. A long, straight laparoscopic forceps was used at the left side. The Multifire Endo-TA 30 stapler and the ENDO CATCH II pouch were directly inserted through the opening in the gel that was manually created on the GelPOINT platform (Fig. 1D). A 10F diameter

The Std-LDN procedure

The Std-LDN procedure has been described previously.24 In brief, a 12-mm camera trocar was inserted in the pararectal line at the level of the umbilicus using an open laparotomy technique. A rigid 10-mm 30-degree digital laparoscope was used. A 5-mm left-hand trocar and a 12-mm right-hand trocar were inserted into the pararectal line 6–7 cm cranial to the umbilicus and under the costal arch of the anterior axillary line. A 12-mm assistant trocar was inserted at the side of the umbilicus, and the assistant trocar wound was extended by 5 or 6 cm to allow loading of a LapDisk (Hakko Medical, Tokyo, Japan) immediately before division of vessels. The Multifire Endo-TA 30 stapler was inserted through the 12mm right-hand trocar. The graft kidney was extracted using an ENDO CATCHTM II 15-mm specimen pouch (Covidien) inserted through the LapDisk. A 5-mm diameter drain was placed using a 5-mm left-hand working trocar. The LEPODN procedure

The LEPODN procedure has been described previously.19 In brief, the GelPOINT (or the GelPort in the first half of the cases) platform was placed on the pararectal incision

FIG. 2. Intraoperative photographs of the GelPOINT configuration in the laparoendoscopic single-site-plus-onetrocar donor nephrectomy (A) and laparoendoscopic single-site donor nephrectomy (B) procedures.

Std-LDN = standard laparoscopic donor nephrectomy; LEPODN = laparoendoscopic single-site-plus-one-trocar donor nephrectomy; LESSDN = laparoendoscopic single-site donor nephrectomy; SD = standard deviation; BMI = body mass index.

0.158 0.165 0.514 0.596

0.979 0.079 0.299 0.708 0.990 0.466 0.231 0.849 0.126 0.995 0.985 0.992 0.346 0.199 0.954 0.376 0.272 0.775 0.964 0.085 0.985

Age, mean – SD, (range) 57.6 – 11.3 (25–79) 58.3 – 11.3 (26–79) 58.8 – 8.2 (41–75) Men/women 24/35 16/15 10/27 Height (cm), mean – SD, (range) 157.8 – 8.8 (140.2–180.0) 160.7 – 8.8 (146.7–179.1) 157.7 – 6.9 (140.0–176.5) Weight (kg), mean – SD, (range) 60.3 – 11.2 (38.1–99.1) 61.9 – 8.9 (43.2–89.0) 59.9 – 10.2 (39.5–77.6) BMI, mean – SD, (range) 24.1 – 4.1 (18.2–38.5) 24.0 – 3.2 (17.7–31.3) 24.1 – 4.2 (16.3–37.6) Single/multiple renal arteries 50/9 20/10 29/8 Preoperative creatinine clearance 111.9 – 32.4 (58.8–200.0) 113.0/26.0 (56.5–162.2) 101.5/22.9 (46.5–148.6) (mL/min), mean – SD, (range) Preoprative serum creatinine (mg/dL), 0.61 – 0.15 (0.44–0.92) 0.64 – 0.13 (0.40–0.81) 0.59 – 0.12 (0.39–0.83) mean – SD, (range)

LESSDN n = 37

The demographic characteristics of all donors, who underwent the Std-LDN, LEPODN, and LESSDN procedures, are shown in Table 1. No significant differences in the donor age, height, weight, body mass index, preoperative creatinine clearance, and serum creatinine levels were noted among the three procedures (Table 1). All 37 LESSDN procedures were completed with the use of only straight instruments and without any additional trocars beyond the working port on the GelPOINT device. Significant differences in the mean operative time, estimated blood loss, and WIT were found among the three procedures (P = 0.012, P = 0.007, and P < 0.001, respectively, one-factor ANOVA). The estimated blood loss and WIT were significantly shorter for the LEPODN procedure than the Std-LDN procedure (P = 0.027 and P = 0.017, respectively, TukeyKramer test). The mean operative time, estimated blood loss, and WIT were significantly shorter for the LESSDN procedure than for the Std-LDN procedure (P = 0.009, P = 0.022, and P < 0.001, respectively, Tukey-Kramer test). No significant differences in perioperative variables were found between the LEPODN and LESSDN procedures (Table 2). Conversion to open surgery and blood transfusions were not needed in any of the three procedures. With the Std-LDN procedure, three patients experienced Clavien grade I complications, including two wound infections and one pneumothorax because of diaphragm injury, which did not necessitate any intervention. With the LESSDN procedure, two patients experienced a Clavien grade I complication, including a case of wound infection and a case of chylous ascites. There were no complications with the LEPODN procedure. No significant differences in postoperative surgical complications and DGF rates were observed among the three procedures. No significant differences in the mean time to oral intake were observed among the three procedures. The time to ambulation and length of postoperative hospital stay were significantly shorter with the LESSDN procedure than with the Std-LDN procedure (P = 0.022 and P = 0.001, respectively, Tukey-Kramer test). No significant differences were found in mean serum creatinine levels of donors or recipients 7 days postoperatively among the three procedures. DGF occurred in two recipients undergoing both LEPODN and LESSDN procedures. With the LEPODN procedure, acute tubular necrosis of the graft caused DGF in two patients. With the LESSDN procedure, acute tubular necrosis caused DGF in one patient and heart failure from fluid overload for postoperative bleeding in another patient. A total of 126 consecutive LDNs were performed by 12 surgeons, including 2 senior (T.H. and N.T.) and 10 junior surgeons. The Std-LDN, LEPODN, and LESSDN procedures

LEPODN n = 30

Results

P

Statistical analyses were performed using the SPSS ver. 22.0 software (SPSS, Inc., Chicago, IL). Fisher exact test, one-factor analysis of variance (ANOVA) test, and TukeyKramer test were used to examine differences among the three procedures. A P value of < 0.05 was considered statistically significant.

Table 1. Demographic Data of Consecutive Donors of 59 Standard Laparoscopic Donor Nephrectomy, 30 Laparoendoscopic Single-Site-Plus-One-Trocar Donor Nephrectomy, and 37 Laparoendoscopic Single-Site Donor Nephrectomy

Statistical analyses

Std-LDN n = 59

drain was intraperitoneally placed in the middle of the single pararectal incision.

0.858 0.221 0.241 0.700 0.967 0.275 0.190

INOUE ET AL.

Std-LDN Std-LDN LEPODN Std-LDN, vs vs vs LEPODN LEPODN LESSDN LESSDN vs LESSDN

4

5

222.9 – 36.3 (154–304) 42.2 – 67.8 (0–347) 224.9 – 68.2 (14– 485) 0 (0.0 %) 0 (0.0 %) 2 (5.4 %) 1.14 – 0.35 (1–2) 1.32 – 0.58 (1–3) 7.38 – 2.03 (6–15) 1.01 – 0.20 (0.68–1.58) 1.48 – 1.16 (0.61–7.64) 2 (5.4%)

40.6 – 54.7 (0–191) 275.7 – 105.9 (140–587) 0 (0.0 %) 0 (0.0 %) 0 (0.0 %) 1.13 – 0.34 (1–2) 1.50 – 0.68 (1–3) 7.93 – 1.25 (6–10) 1.09 – 0.22 (0.74–1.64) 1.50 – 1.35 (0.46–7.67) 2 (6.5%)

LESSDN n = 37

234.3 – 41.9 (154–318)

LEPODN n = 30

0.135 0.800 0.111

0.028

0.332

0.017 1.000 1.000 0.186 0.979

0.027

0.328

0.963 0.834 0.146

0.001

0.022

< 0.001 1.000 1.000 0.575 0.970

0.022

0.009

Std-LDN vs LESSDN

0.277 0.995 0.610

0.760

0.580

0.081 1.000 1.000 0.498 1.000

0.995

0.425

LEPODN vs LESSDN

0.144 0.763 0.155

0.001

0.027

< 0.001 1.000 1.000 0.356 0.966

0.007

0.012

Std-LDN, LEPODN vs LESSDN

Std-LDN = standard laparoscopic donor nephrectomy; LEPODN = laparoendoscopic single-site-plus-one-trocar donor nephrectomy; LESSDN = laparoendoscopic single-site donor nephrectomy; SD = standard deviation; WIT = warm ischemic time; DGF = delayed graft function.

Operative time (min), mean – SD, 246.2 – 35.3 (166–342) (range) Estimated blood loss (mL), 79.5 – 70.2 (0–269) mean – SD, (range) WIT (sec), mean – SD, (range) 333.3 – 104.9 (129–811) Open surgery conversion 0 (0.0 %) Blood transfusion 0 (0.0 %) Postoperative surgical complication 4 (6.8 %) Time to oral intake (day), 1.11 – 0.32 (1–2) mean – SD, (range) Time to ambulation (day), 1.72 – 0.80 (1–4) mean – SD, (range) Postoperative hospital stay (day), 9.79 – 4.27 (5–37) mean – SD, (range) Postoperative serum creatinine (mg/dL), mean – SD, (range) Donor 7 day 1.00 – 0.20 (0.61–1.63) Recipient 7 day 1.34 – 0.92 (0.50–6.28) DGF 0 (0.0%)

Std-LDN n = 59

Std-LDN vs LEPODN

p

Table 2. Comparison of Perioperative Data Between 59 Standard Laparoscopic Donor Nephrectomy, 30 Laparoendoscopic Single-Site-Plus-One-Trocar Donor Nephrectomy, and 37 Laparoendoscopic Single-Site Donor Nephrectomy

Std-LDN = standard laparoscopic donor nephrectomy; LEPODN = laparoendoscopic single-site-plus-one-trocar donor nephrectomy; LESSDN = laparoendoscopic single-site donor nephrectomy; SD = standard deviation.

0.203 0.400 0.950 0.432 0.818 0.860 0.974 0.790 0.179 0.576 0.951 0.783 0.647 0.377 1.000 0.421 0.004 0.414 0.713 0.118 0.087 0.848 0.690 0.109 0.004 0.603 0.929 0.988 0.728 0.388 0.839 0.109 21 – 32 56 – 119 40 – 44 49 – 87 214 – 26 209 – 24 240 – 47 265 – 28 10 8 7 5 42 – 83 33 – 15 52 – 45 10 – 4 251 – 29 198 – 30 213 – 33 226 – 49 5 5 3 3 73 – 73 114 – 80 51 – 22 79 – 87 10 4 8 10 1 2 3 4

264 – 36 228 – 45 231 – 50 268 – 24

n

Estimated Estimated Operative blood Operative blood time (min), loss (mL), time (min), loss (mL), mean – SD mean – SD n mean – SD mean – SD Junior surgeon No.

Std-LDN

LEPODN

n

Estimated Std-LDN, Std-LDN, Operative blood Std-LDN Std-LDN LEPODN LEPODN Std-LDN Std-LDN LEPODN LEPODN time (min), loss (mL), vs vs vs vs vs vs vs vs mean – SD mean – SD LEPODN LESSDN LESSDN LESSDN LEPODN LESSDN LESSDN LESSDN

LESSDN

P (operative time)

P (estimated blood loss)

INOUE ET AL.

Table 3. Comparison of Operative Time and Estimated Blood Loss Between Standard Laparoscopic Donor Nephrectomy, Laparoendoscopic Single-Site-Plus-One-Trocar Donor Nephrectomy, and Laparoendoscopic Single-Site Donor Nephrectomy in Four Representative Junior Surgeons Who Performed Laparoendoscopic Single-Site Donor Nephrectomy

6

were performed by 10, 10, and 7 surgeons, respectively. Of the 10 junior surgeons who performed the Std-LDN procedure, 8 performed the LEPODN procedure and 5 performed the LESSDN procedure. With regard to Std-LDN and LEPODN, two and three junior surgeons did not follow the next procedure because of job relocation, respectively. The five junior surgeons performed 3–5 LEPODN procedures before they performed the LESSDN under the guidance of senior surgeons. Individual data of the 4 junior surgeons, including the operative time and estimated blood loss, are shown in Table 3. The data of the fifth junior surgeon were excluded because he performed only one LESSDN procedure (Table 3). There were no statistically significant differences in the operative time and estimated blood loss among the three procedures for the four junior surgeons. The operative time, however, with the LESSDN procedure was significantly shorter than that with the Std-LDN procedure for one junior surgeon (P = 0.004, Tukey-Kramer test). Discussion

We developed the LEPODN reduced-port procedure before the application of the LESSDN procedure as a useful technical bridge.19 An additional 5-mm right-hand trocar was added to the LESSDN procedure to broaden the triangulation of straight instruments and to facilitate the LESSDN procedure. Acceptable morbidity rates and favorable graft function were observed with the use of the LEPODN procedure. All 30 LEPODN procedures in this series were performed by 10 surgeons who were comfortable with conventional laparoscopic surgery using standard straight instruments. The results of the LEPODN procedure suggest that the technical concept and difficulty of the LEPODN procedure were similar to those of the Std-LDN procedure. The additional 5-mm right-hand trocar used in the LEPODN procedure was removed in the LESSDN procedure after the LEPODN procedure was performed several times. A similar procedure concept using the GelPort in the single pararectal incision was initially reported by Ponsky and associates25 for radical nephrectomy. The trocar formation on the GelPOINT platform was modified from that of the LEPODN procedure to optimize the LESSDN procedure in this series (Fig. 1B, 1D). To avoid hand collisions between the instruments and the camera, a rigid 30-degree camera 5 mm in diameter and 50 cm in length, a 90-degree light adapter, and a relatively long (43 cm) bipolar straight forceps were used in the LESSDN procedure. With these three instruments, the surgeons’ hands could be kept at a sufficient distance, allowing smooth movements of the straight instruments. Stamatakis and colleagues17 reported the successful use of the ‘‘extra-long nondeflectable instruments’’ in a series of LESSDN procedures using the GelPOINT in the umbilical single incision, similar to that reported in our study. The optimization of device arrangements seems indispensable for the execution of the LESSDN procedure, although these arrangements may be influenced by the familiar customs at each institute. The operative time was the shortest with the LESSDN procedure in the present series. Compared with the Std-LDN procedure, previous LESSDN series have shown equal10,14–16 or increased11,12,17 operative time. Moreover, the estimated blood loss was less in the LEPODN and LESSDN procedures

LESS AFTER LESS-PLUS-ONE DONOR NEPHRECTOMY

7

than in the Std-LDN procedure. The success of the LESSDN procedure in this series may result from the improvement of the surgeon’s technique as well as the effectiveness of the introductory LEPODN procedure, which provided an ideal technical bridge for surgeons to learn the LESSDN procedure. The concepts and techniques involved in the LESSDN procedure were shared among the seven surgeons, including the two senior surgeons. All surgeons successfully and safely completed the LESSDN procedure without using flexible instruments. The shortened operative time of one of the junior surgeons in the LESSDN procedure suggested that the surgical technique of the surgeon could be improved and refined despite the technical burden of the LESS surgery. In their LESSDN report, Stamatakis and coworkers17 stated that they had abandoned their earlier approach to place the additional 6-mm port in a subxiphoid location because of their technical improvement. Our strategy, however, consisted of using the same concept as the LEPODN procedure to teach multiple surgeons instead of abandoning the approach. In the present series, WIT was the shortest with the LESSDN procedure. Stamatakis and associates17 also reported shorter WIT with the LESSDN procedure than with the Std-LDN procedure because of the usefulness of the GelPOINT platform. With the LEPODN and LESSDN procedures in this series and other recently reported studies, the single incision was made at the beginning of the surgery to extract the kidney graft quickly without extending the incision.12,13,15–19 In some initial reports of the LESSDN procedure, however, the laparoscopic procedure was performed using a small 2-cm single incision, then the incision was extended to 4–5 cm to extract the donor kidney after dividing the renal vessels. In this strategy, WIT with the LESSDN procedure was reported to be significantly longer than that with the Std-LDN procedure.10,14 During our Std-LDN procedure, the extraction site was extended right before dividing the renal vessels, and the LapDisk was applied instead of the GelPOINT platform. The shortened WIT with the LESSDN procedure in this series may not be a result of the wound extension timing of the extracting site but rather a result of the higher stability of the GelPOINT device than the LapDisk in the extracting procedure or improvement of our extraction technique during these three procedures. There are some limitations of this study. First, to assess the real effect of the LEPODN procedure as the technical bridge, the control results of the transition from Std-LDN to LESSDN procedures directly without the LEPODN procedure should be evaluated. The direct strategy, however, should not be recommended because the LESSDN procedure is still an investigational procedure and donor safety must be prioritized.16 Second, the number of cases in this series was small for each procedure and for each surgeon. Third, we did not compare the pain score and wound length to confirm whether there was less morbidity with the LESS procedure because of lack of these data in the Std-LDN procedure era. The shorter ambulation and hospitalization days in this study, however, may indicate lesser morbidity with the LEPODN or LESSDN procedure than with the Std-LDN procedure. These results should be interpreted with care, considering the technical improvement during the three procedures, because the data of the Std-LDN procedure were historical retrospective data in this series. Further prospective investigation in a large sample is warranted to assess the real effect

of our strategy to use the LEPODN procedure before the LESSDN procedure. Fourth, the incision of our procedure was not placed umbilically but was placed pararectally, which could be relatively conspicuous but safer for donors. The reason is that we have performed conventional laparoscopic nephrectomy safely with a pararectal camera port in many patients. From the standpoint of cosmesis, the next step may be LESSDN with an umbilical camera port. Conclusion

The LESSDN procedure can be introduced safely and effectively without compromising the operative time, complication rates, and graft function after multiple surgeons have gained technical experience by previously performing the LEPODN procedure. Thus, the LEPODN procedure may be an effective bridge from standard multiport LDN to LESSDN. The GelPOINT platform facilitated the LESSDN procedure and helped avoid the use of articulating instruments. Although the LESSDN procedure should still be considered as investigational and challenging, previous experience with the LEPODN procedure may be helpful in safely incorporating LESS procedures in the field of LDN. Disclosure Statement

No competing financial interests exist. References

1. Dols LF, Kok NF, Ijzermans JN. Live donor nephrectomy: A review of evidence for surgical techniques. Transpl Int 2010;23:121–130. 2. Raman JD, Bensalah K, Bagrodia A, et al. Laboratory and clinical development of single keyhole umbilical nephrectomy. Urology 2007;70:1039–1042. 3. Rane´ A, Rao P, Rao P. Single-port-access nephrectomy and other laparoscopic urologic procedures using a novel laparoscopic port (R-port). Urology 2008;72:260–264. 4. Tracy CR, Raman JD, Cadeddu JA, Rane A. Laparoendoscopic single-site surgery in urology: Where have we been and where are we heading? Nat Clin Pract Urol 2008;5:561–568. 5. Fan X, Lin T, Xu K, et al. Laparoendoscopic single-site nephrectomy compared with conventional laparoscopic nephrectomy: A systematic review and meta-analysis of comparative studies. Eur Urol 2012;62:601–612. 6. Symes A, Rane A. Urological applications of single-site laparoscopic surgery. J Minim Access Surg 2011;7:90–95. 7. Ratner LE, Sandoval PR. When disaster strikes: Death of a living organ donor. Am J Transplant 2010;10:2577–2581. 8. Gill IS, Canes D, Aron M, et al. Single port transumbilical (E-NOTES) donor nephrectomy. J Urol 2008;180:637–641. 9. Ganpule AP, Dhawan DR, Kurien A, et al. Laparoendoscopic single-site donor nephrectomy: A single-center experience. Urology 2009;74:1238–1240. 10. Canes D, Berger A, Aron M, et al. Laparo-endoscopic single site (LESS) versus standard laparoscopic left donor nephrectomy: Matched-pair comparison. Eur Urol 2010;57: 95–101. 11. Andonian S, Rais-Bahrami S, Atalla MA, et al. Laparoendoscopic single-site Pfannenstiel versus standard laparoscopic donor nephrectomy. J Endourol 2010;24:429–432. 12. Ramasamy R, Afaneh C, Katz M, et al. Comparison of complications of laparoscopic versus laparoendoscopic

8

13. 14.

15.

16. 17.

18.

19. 20. 21. 22.

INOUE ET AL.

single site donor nephrectomy using the modified Clavien grading system. J Urol 2011;186:1386–1390. Gimenez E, Leeser DB, Wysock JS, et al. Laparoendoscopic single site live donor nephrectomy: Initial experience. J Urol 2010;184:2049–2053. Kurien A, Rajapurkar S, Sinha L, et al. First prize: Standard laparoscopic donor nephrectomy versus laparoendoscopic single-site donor nephrectomy: A randomized comparative study. J Endourol 2011;25:365–370. Afaneh C, Aull MJ, Gimenez E, et al. Comparison of laparoendoscopic single-site donor nephrectomy and conventional laparoscopic donor nephrectomy: Donor and recipient outcomes. Urology 2011;78:1332–1337. Wang GJ, Afaneh C, Aull M, et al. Laparoendoscopic single-site live donor nephrectomy: Single institution report of initial 100 cases. J Urol 2011;186:2333–2337. Stamatakis L, Mercado MA, Choi JM, et al. Comparison of laparoendoscopic single site (LESS) and conventional laparoscopic donor nephrectomy at a single institution. BJU Int 2013;112:198–206. Chueh SC, Sankari BR, Lipscomb L, et al. Safe initiation of a laparoendoscopic single site living donor nephrectomy program in a small-volume transplant center. Urology 2013;82:352–357. Inoue T, Tsuchiya N, Narita S, et al. Laparoendoscopic single-site plus one trocar donor nephrectomy using the GelPort: Initial clinical experience. Urology 2013;81:308–312. Tsuchiya N, Iinuma M, Habuchi T, et al. Hand-assisted retroperitoneoscopic nephrectomy for living kidney transplantation: Initial 44 cases. Urology 2004;64:250–254. Tsuchiya N, Satoh S, Sato K, et al. Hand assisted retroperitoneoscopic living donor nephrectomy in elderly donors. J Urol 2006;175:230–234. Narita S, Inoue T, Matsuura S, et al. Outcome of right hand-assisted retroperitoneoscopic living donor nephrectomy. Urology 2006;67:496–501.

23. Dindo D, Demartines N, Clavien PA. Classification of surgical complications: A new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg 2004;240:205–213. 24. Saito M, Tsuchiya N, Narita S, et al. Comparison of the clinical outcome and systemic inflammatory marker levels between retroperitoneal and transperitoneal laparoscopic donor nephrectomy. J Endourol 2012;26:1038–1043. 25. Ponsky LE, Cherullo EE, Sawyer M, Hartke D. Single access site laparoscopic radical nephrectomy: Initial clinical experience. J Endourol 2008;22:663–666.

Address correspondence to: Tomonori Habuchi, MD Department of Urology Akita University School of Medicine 1-1-1 Hondo Akita 010-8543 Japan E-mail: [email protected]

Abbreviations Used ANOVA ¼ analysis of variance DGF ¼ delayed graft function LDN ¼ laparoscopic donor nephrectomy LEPODN ¼ laparoendoscopic single-site-plusone-trocar donor nephrectomy LESS ¼ laparoendoscopic single-site LESSDN ¼ laparoendoscopic single-site donor nephrectomy Std-LDN ¼ standard laparoscopic donor nephrectomy WIT ¼ warm ischemia time

Successful introduction of laparoendoscopic single-site donor nephrectomy after experience with laparoscopic single-site plus-one trocar donor nephrectomy.

To assess the feasibility, safety, and efficacy of the laparoendoscopic single-site (LESS) donor nephrectomy (LESSDN) procedure after experience with ...
264KB Sizes 5 Downloads 5 Views