Sensors 2014, 14, 868-876; doi:10.3390/s140100868 OPEN ACCESS

sensors ISSN 1424-8220 www.mdpi.com/journal/sensors Article

Stretchable and Flexible High-Strain Sensors Made Using Carbon Nanotubes and Graphite Films on Natural Rubber Sreenivasulu Tadakaluru, Wiradej Thongsuwan and Pisith Singjai * Materials Science Research Center, Department of Physics and Materials Science, Faculty of Science, Chiangmai University, Chiangmai 50200, Thailand; E-Mails: [email protected] (S.T.); [email protected] (W.T.) * Author to whom correspondence should be addressed; E-Mail: [email protected]; Tel.: +66-538-922-71; Fax: +66-538-922-70. Received: 12 November 2013; in revised form: 23 December 2013 / Accepted: 24 December 2013 / Published: 6 January 2014

Abstract: Conventional metallic strain sensors are flexible, but they can sustain maximum strains of only ~5%, so there is a need for sensors that can bear high strains for multifunctional applications. In this study, we report stretchable and flexible high-strain sensors that consist of entangled and randomly distributed multiwall carbon nanotubes or graphite flakes on a natural rubber substrate. Carbon nanotubes/graphite flakes were sandwiched in natural rubber to produce these high-strain sensors. Using field emission scanning electron microscopy, the morphology of the films for both the carbon nanotube and graphite sensors were assessed under different strain conditions (0% and 400% strain). As the strain was increased, the films fractured, resulting in an increase in the electrical resistance of the sensor; this change was reversible. Strains of up to 246% (graphite sensor) and 620% (carbon nanotube sensor) were measured; these values are respectively ~50 and ~120 times greater than those of conventional metallic strain sensors. Keywords: piezoresistive sensor; soft wearable sensors; electro-mechanical properties; film composite; stretchable device; carbon nanotubes; health monitoring

1. Introduction Piezoresistive materials are materials in which the electrical resistance is a function of the internal strain [1]. Piezoresistive strain sensors can be grouped into two types; flexible, and flexible and

Sensors 2014, 14

869

stretchable sensors. Metallic strain sensors and polymer composite-based strain sensors are examples of flexible and flexible and stretchable strain sensors, respectively. Metallic strain sensors are widely used; the maximum strain measurable with these sensors is 5% [2]. There are a number of different types of polymer-based strain sensors [3]. They are typically made using conductive fillers such as single-walled carbon nanotubes, multiwalled carbon nanotubes (MWCNTs), carbon black, graphite in a polymer matrix, or film composites [4–6]. Polymer composite strain sensors offer a maximum measurable strain that is greater than that of metallic strain sensors. Sensors that can measure high strains typically show lower sensitivity, and highly sensitive sensors typically offer small maximum measurable strains [7,8]. Yamada et al. introduced a different method for the fabrication of strain sensors using aligned carbon nanotubes. These sensors could measure strains of up to 280% (sensitivity 0.82–0.06); the authors reported that maximum strains of only ~5% were measurable using randomly aligned single wall carbon nanotubes [9]. Shin et al. reported a maximum measurable strain of up to 300% with a sensitivity 0.34–1.07 using a MWCNT forest [10]. Although these sensors’ measurable strains were high, the sensitivity values were lower than those of commercially available metallic strain sensors, whose sensitivity typically has a value of 2. Here, we report two types of strain sensors fabricated by sandwiching conductive films between natural rubber (NR) layers, where the conductive layers consisted of randomly distributed, entangled MWCNTs, or graphite flakes. These two types of sensors could measure high strains of up to 620% (MWCNT sensor) and 246% (graphite sensor), with high sensitivities of 5–43 and 12–346, respectively. The effect of the sample dimensions (width, length) on the sensitivity and growth rate of the relative resistance was also investigated. Most of the reported sensors’ response curves are nonlinear, so the application of a linear fit leads to large errors. To solve this problem, we introduce a linearization method to linearize the exponential response curves. 2. Experimental Section 2.1. Fabrication of Multiwalled Carbon Nanotube/Graphite Flake Strain Sensors MWCNTs were synthesized using the CVD method [11], and graphite powder was purchased from Merck Chemicals Darmstadt, Germany. These two carbon allotropes were chosen as conducting powders. The NR substrate (thickness 0.080 mm) was pre-stretched, and MWCNT/graphite powder was coated on the substrate by gently rubbing the powder on the surface by hand (MWCNT: ~0.109 mg/cm2, graphite: ~0.16 mg/cm2, thickness: ~10–20 µm). The graphite/MWCNTs adhered well to the NR surface because of the surface stickiness of NR; this stickness included a dispersive adhesion mechanism as well as a chemical adhesion mechanism (no adhesives were used). This MWCNT-coated NR sheet was then cut into several samples. In the experiments, the two ends of the MWCNT-coated NR sample were strongly glued on two supporting acrylic pieces. Two electric wires were attached at the ends of the sample, using silver paint (on the strongly glued area of the sample). Because the silver paint was on the strongly glued, unstretchable area of the sample, no cracking of the silver paint occurred during the stretching of the sample. After the preparation of the electrodes, the sample was sealed with liquid natural rubber and dried. This sandwiched, middle layer of MWCNTs between the two NR layers acted as a strain sensor.

Sensors 2014, 14

870

The graphite sensors were prepared in the same way as the MWCNT sensors. A schematic diagram of the key sample fabrication steps is shown in Figure 1, and the surface morphologies (unsealed sample) of 0%- and 400%-strained MWCNT and graphite samples are shown in Figure 2. The FE-SEM micrographs showed that even at high strains, there was still a conducting path between the nanotubes, and between the graphite flakes. These results suggested that the sensors would have a measurable strain range. Figure 1. Schematic illustration of the steps used to prepare the test samples, which consisted of MWCNTs or graphite coated on NR.

Figure 2. (a,b) SEM images of unstrained (0%) and strained (400%) MWCNT-coated NR samples; (c,d) SEM images of unstrained (0%) and strained (400%) graphite-coated NR samples.

Sensors 2014, 14

871 Figure 2. Cont.

3. Results and Discussion 3.1. Electrical Resistance Measurements The MWCNT sandwich sample (gauge length 2 cm, width 1 cm) was stretched using a constant strain rate of 8.3% s−1, up to a strain of 620% (giving a final sample length of 14.4 cm). For the graphite flake sandwich sample (active gauge length 2 cm, width 1 cm), the maximum measured strain was 246% (giving a final sample length of 6.92 cm). The electrical resistance was measured by using Kelvin (4-wire) method. The resistance and relative change in resistance versus strain response curves are shown in Figure 3 for the MWCNT and graphite samples. Figure 3. Response curves: (a) Relative resistance and resistance versus strain response curves for the MWCNT sensor; (b) Relative resistance and resistance versus strain response curves for the graphite sensor.

250

60M

MWCNT

50M 40M

150

30M

100

20M

50

10M

0

0 0

1

2

3 4 Strain, L/L0

5

6

7

800

250M Graphite 200M

600

150M

400

100M

200

50M

0

Resistance (Ohm)

200

Relative resistance,R/R0

b 1000

300

Resistance (Ohm)

Relative resistance, R/R0

a

0 0.0

0.5

1.0

1.5

2.0

2.5

3.0

Strain, L/L0

The resistance increased with the strain [1,4,5,7]. The carbon nanotube sensor showed a higher measurable strain limit (620%) compared with the graphite sensor (246%); this was likely because the nanotubes had a smaller size, compared with the graphite flakes. The sensitivity was calculated in terms of the gauge factor, using the formula gauge factor (GF) = relative resistance/strain, i.e.,

Sensors 2014, 14

872

GF = [(R − R0)/R0]/[(L − L0)/L0], where R0 and L0 are the initial resistance and initial length of the sample, respectively. The sensitivity increased linearly with increasing applied strain for the MWCNT sensor, and the sensitivity increased exponentially with increasing applied strain for the graphite sensor. The sensitivity values for the MWCNT sensors were 5.5, 10.2, 16.3, 23.1, 31.5, and 43.4 at 100%, 200%, 300%, 400%, 500%, and 620% strain, respectively. The sensitivity values for the graphite sensors were 23.7, 37.5, 148.1, and 346.6 at 50%, 100%, 200%, and 246% strain, respectively. The relative change in the resistance response curves for the MWCNT and graphite sensors was nonlinear. It is likely that this nonlinear behavior resulted from the non-uniform fracturing/deformation of the conducting layers on the NR. When the sensor was subjected to stretch, the width contracted perpendicular to the longitudinal strain axis. During stretching, the freedom of the polymer chains to undergo contraction (perpendicular to the longitudinal strain axis) decreased exponentially with distance from the ends. This width contraction (or the lateral strain), was much lower at the sample’s two ends, compared with the middle of the sample. This was because the sample ends were strongly bonded to the acrylic holding substrate with super-glue (Figure 4a). The stress versus strain curves for the MWCNT, graphite coated, and uncoated NR samples were identical and nonlinear (i.e., they did not obey Hook’s law) (Figure 4b). At the ends of the sample where the polymer chains had less freedom to undergo contraction, the level of fracturing in the conducting layer was higher. This resulted in a reduction in the electrical percolation/number of tunneling contacts with increasing strain. The tunneling resistance may therefore have increased with the decrease in the electrical percolation/number of tunneling contacts [12–14]. Figure 4. Nonlinearity: (a) Non-uniform deformation of the strained conducting layer/substrate; (b) Stress versus strain curves for the MWCNT, graphite coated, and uncoated NR samples.

b 13.2M

CNT coated NR Graphite Coated NR NR (with out coating)

2

Stress (N/m )

9.9M 6.6M 3.3M 0.0 -1

0

1

2

3 Strain

4

5

6

7

3.2. Effect of Sensor Size on Linearity and Sensitivity MWCNT and graphite sensors were prepared with a constant width of 10 mm, and three different lengths (active gauge lengths of (A) 20 mm; (B) 10 mm; and (C) 5 mm were prepared). The three

Sensors 2014, 14

873

samples A, B, and C were stretched using a constant strain rate of ~8% s−1, and the electrical resistance was recorded. The longest MWCNT sensors and graphite sensors (10 × 20 mm) showed higher sensitivity than the shorter samples in the lower strain range. The shorter samples’ response curves were highly nonlinear compared with the long samples, and at higher strain values the sensitivities of the shorter MWCNT samples surpassed the long samples’ sensitivity. The measured relative resistance growth rate for the MWCNT sensors using sample sizes of W × L = 10 × 20 mm, 10 × 10 mm, and 10 × 5 mm were 0.548, 0.773, and 0.870, and those for the graphite sensors were 2.262, 2.298, and 2.430. The relative change in resistance versus strain and the sensitivity versus strain are shown in Figure 5 for the three different samples (A, B, and C). Figure 5. Size dependent sensitivity: (a) MWCNT sensors with dimensions (width × length) of 10 × 20 mm (A1, A2, A3); 10 × 10 mm (B1, B2, B3); and 10 × 5 mm (C1, C2, C3); (b) Graphite sensors with dimensions (width × length) of 10 × 20 mm (A1, A2, A3); 10 × 10 mm (B1, B2, B3); 10 × 5 mm (C1, C2); (c,d) Sensitivity versus strain curves for MWCNT and graphite sensors with dimensions of 10 × 20 mm (A), 10 × 10 mm (B), and 10 × 5 mm (C).

300

200

100

0 0

1

900

b

cnt A1 cnt A2 cnt A3 cnt B1 cnt B2 cnt B3 cnt C1 cnt C2 cnt C3

400

Relative resistance, R/R0

Relative resistance, R/R0

a

2

3

4

5

6

gra A1 gra A2 gra A3 gra B1 gra B2 gra B3 gra C1 gra C2

750 600 450 300 150 0

7

0

1

Strain, L/L0 80

350

d 300

20

70

15

60

10

50

5

40

0 0.0

30

0.2

0.4

0.6

0.8

1.0

20

0

4

60 40

1

2

3

4

Strain, L/L0

5

6

200

0 0.0 0.2 0.4 0.6 0.8 1.0

150 100 50

cnt A cnt B cnt C

10 0

3

250 20

Sensitivity, GF

Sensitivity, GF

c

2

Strain, L/L0

gra A gra B gra C

0

7

0

1

2

3

4

Strain, L/L

For typical metallic strain sensors, the gauge factor value is constant (~2) up to the maximum strain limit of 5%. Slobodian et al. [15] reported a sensor that could measure strains of up to 400% (MWCNT network in polyurethane); even at low strain values, its sensitivity changed linearly. Shin et al. reported a sensor (MWCNT forest in polyurethane) that showed constant sensitivity (0.34)

Sensors 2014, 14

874

up to a 30% strain limit. Yamada et al. reported constant sensitivity (0.82) up to a 40% strain limit. In the present work, the MWCNT/graphite sensor showed a constant sensitivity (5/12) for strain values of up to 100%. 3.3. Multiple Cycle Tests One end of the MWCNT strain sensor sample was attached to a disk, which was rotating with an angular velocity of 2 radians·s−1. The applied sinusoidal strain (with a period of ~3.04 s) ranged between 150% and 500%, and the total number of cycles was more than 400 (Figure 6).

Relative resistance (R/R0)

Figure 6. Multiple cycle tests: More than 400 cycles of period 3.04 s were carried out for the strain range of 150%–500%. (Inset image: the first 16 full cycles carried out over a time period of 48.6 s). 150

460 cycles

140

100

70 0

50 0

0

200

0

10

400

20

600

30

40

50

800 1000 1200 1400 1600 Time (sec)

3.4. Linearization of Nonlinear Response Curves Metallic strain sensors’ response curves are linear up to ~5% of the maximum strain limit; for small strain values, therefore, the response curve for the graphite sensor appeared to be linear. However, the response curve over the whole region from 0% to 300% strain showed that this linearity was merely an approximation to the early part of an exponential curve. The linear response curve of conventional metallic strain sensors can therefore be considered as a small part of an exponential curve. A linear fit to an exponential response curve results in large errors. However, these exponential response curves could be linearized by connecting an external resistor parallel to the strain sensor. Resistance curves for the graphite sensor with and without a 2 MΩ parallel resistance are shown in Figure 7. The coating of the MWCNT/graphite flakes on the prestretched substrate helped to maintain the electrical percolation and conducting pathways between the two electrodes (electric leads), even at high strains. Axial strain was applied using a lab-made speed control device. The two electrical leads from the test sample were connected to a constant power supply of 5 V (laboratory D.C power supply, GPC-1850D, Tucheng, New Taipei, Taiwan). The current flow in the circuit was measured using a Keithley-196 system DMM instrument, Cleaveland, Ohio, USA. The voltage drop across the sensor was measured (Kelvin method or 4-wire method) using a Hewlett Packard data acquisition-34970A (Santa Clara, CA, USA) instrument, and the output resistance was recorded using a computer. The surface morphology of the strained films was observed using FE-SEM (JSM-6335F, JEOL, Akishima, Tokyo, Japan).

Sensors 2014, 14

875

Figure 7. Linearization: response curves for graphite sensor with (blue) and without (black) a 2 MΩ parallel resistor. Gra sensor Gra sensor ll 2M.Ohm

2M

40M 1M 20M

Resistance (Ohm)

Resistance (Ohm)

60M

0

0 0

1 2 Strain, L/L0

3

4. Conclusions To the best of our knowledge, these results are superior to those of any other previously reported strain sensor, in terms of the simple fabrication, high measurable strain (620%, limited by the substrate properties), and high sensitivity with good durability (400 cycles for 150%–500% strain range). These high-strain sensors could be used as multifunctional sensors [16] to measure, for example, force, speed, pressure, acceleration, frequency, structural vibrations, earthquakes or in health monitoring. The NR substrate has characteristic limitations that prevent its use in some environments, but these limitations could be overcome by replacing the NR substrate with other types of elastomers, for example, silicone rubber. Acknowledgments We thank the National Research University Project under Thailand’s Office of the Commission on Higher Education (CHE) for financial support. Conflicts of Interest The authors declare no conflict of interest. Supplementary Information Response curves of MWCNT and Graphite sensors for different samples/sensors sizes (Figure S1), cross sectional views of MWCNT and Graphite films on natural rubber (Figure S2) and comparison with other reported results (Table S1) were shown in supplementary information. References 1.

Moshfegh, S.; Ebrahimi, N. Strain sensors based on graphite fillers. Iran Polym. J. 2004, 13, 113–119.

Sensors 2014, 14 2. 3. 4.

5. 6.

7. 8.

9.

10. 11.

12. 13.

14. 15.

16.

876

Dobie, W.B.; Isaac, P.C.G. Electric Resistance Strain Gauges; English Universities Press Limited: 1948, Madison, WI, USA. Hu, B.; Chen, W.; Zhou, J. High performance flexible sensor based on inorganic nanomaterials. Sens. Actuators B: Chem. 2013, 176, 522–533. Zou, J.-F.; Yu, Z.-Z.; Pan, Y.-X.; Fang, X.-P.; Ou, Y.-C. Conductive mechanism of polymer/graphite conducting composites with low percolation threshold. J. Polym. Sci. Part B: Polym. Phys. 2002, 40, 954–963. Wang, L.; Ding, T.; Wang, P. Thin flexible pressure sensor array based on carbon black/silicone rubber nanocomposite. IEEE Sens. J. 2009, 9, 1130‒1135. Dinh-Trong, N.; Steitz, J.; Bu, L.; Kanoun, O. Influence of the Composition of MWCNTs Layers on the Properties of Strain Gauges. In Proceedings of the 9th IEEE Conference on Nanotechnology (IEEE-NANO 2009), Genoa, Italy, 26–30 July 2009; pp. 477–480. Li, X.; Zhang, R.; Yu, W.; Wang, K.; Wei, J.; Wu, D.; Cao, A.; Li, Z.; Cheng, Y.; Zheng, Q.; et al. Stretchable and highly sensitive graphene-on-polymer strain sensors. Sci. Rep. 2012, 2, 870. Levin, Z.S.; Robert, C.; Feller, J.F.; Castro, M.; Grunlan, J.C. Flexible latex-polyaniline segregated network composite coating capable of measuring large strain on epoxy. Smart Mater. Struct. 2013, 22, 1–9. Yamada, T.; Hayamizu, Y.; Yamamoto, Y.; Yomogida, Y.; Izadi-Najafabadi, A.; Futaba, D.; Hata, K. A stretchable carbon nanotube strain sensor for human-motion detection. Nat. Nanotechnol. 2011, 6, 296–301. Hin, M.; Oh, J.; Lima, M.; Kozlov, M.; Kim, S.; Baughman, R. Elastomeric conductive composites based on carbon nanotube forests. Adv. Mater. 2010, 22, 2663–2667. Singjai, P.; Changsarn, S.; Thongtem, S. Electrical resistivity of bulk multi-walled carbon nanotubes synthesized by an infusion chemical vapor deposition method. Mater. Sci. Eng. A 2007, 443, 42–46. Hu, N.; Karube, Y.; Arai, M.; Watanabe, T.; Yan, C.; Li, Y.; Liu, Y.; Fukunaga, H. Investigation on sensitivity of a polymer/carbon nanotube composite strain sensor. Carbon 2010, 48, 680–687. Li, X.; Levy, C.; Agarwal, A.; Datye, A.; Elaadil, L.; Keshri, A.K.; Li, M. Multifunctional carbon nanotube film composite for structure health monitoring and damping. Open Constr. Build. Technol. J. 2009, 3, 146–152. Xu, W.; Allen, M.G. Deformable strain sensors based on patterned MWCNTs/polydimethyl-siloxane composites. J. Polym. Sci. Part B: Polym. Phys. 2013, 51, 1505‒1512. Slobodian, P.; Riha, P.; Saha, P. A highly-deformable composite composed of an entangled network of electrically-conductive carbon-nanotubes embedded in elastic poly-urethane. Carbon 2012, 50, 3446–3453. Li, C.; Thostenson, E.T.; Chou, T.-W. Dominant role of tunneling resistance in the electrical conductivity of carbon nanotube-based composites. Appl. Phys. Lett. 2007, 91, 223114:1–223114:3.

© 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).

OPEN ACCESS

sensors ISSN 1424-8220 www.mdpi.com/journal/sensors Supplementary Information

Stretchable and Flexible High-Strain Sensors Made Using Carbon Nanotubes and Graphite Films on Natural Rubber. Sensors 2014, 14, 868-876 Sreenivasulu Tadakaluru, Wiradej Thongsuwan and Pisith Singjai * Materials Science Research Center, Department of Physics and Materials Science, Faculty of Science, Chiangmai University, Chiangmai 50200, Thailand; E-Mails: [email protected] (S.T.); [email protected] (W.T.) * Author to whom correspondence should be addressed; E-Mail: [email protected]; Tel.: +66-538-922-71; Fax: +66-538-922-70.

Figure S1. Effect of sample size on sensitivity and linearity: Response curves of MWCNT (Cnt) and Graphite (Gra) sensors for different samples/sensor sizes [W × L = 10 × 20 mm (A1, A2, A3), 10 × 10 mm (B1, B2, B3), 10 × 5 mm (C1, C2, C3)]. 900

500

Cnt A1 Cnt A2 Cnt A3

WxL: 10x20mm

Gra A1 Gra A2 Gra A3

750

Relative resistance

Relative resistance

400 300 200 100

600 450

WxL: 10x20mm

300 150 0

0 -1

0

1

2

3

Strain

4

5

6

7

-1

0

1

2

3

Strain

4

5

6

7

Sensors 2014, 14

S2

Figure S1. Cont. 500

cnt b1 cnt b2 cnt b3

WxL: 10x10mm

Gra B1 Gra B2 Gra B3

750

Relative resistance

Relative resistance

400

900

300 200 100

600

WxL: 10x10mm

450 300 150 0

0 -1

0

1

2

3

4

5

6

-1

7

0

1

2

6

7

Gra C1 Gra C2 Gra C3

WxL: 10x5mm 750

Relative resistance

Relative resistance

5

900

Cnt C1 Cnt C2 Cnt C3

400

4

Strain

Strain 500

3

300 200 100

600

WxL: 10x5mm 450 300 150 0

0 -1

0

1

2

3

4

5

6

7

-1

Strain

0

1

2

3

4

5

6

7

Strain

Figure S2. Cross sectional views (a) MWCNT and (b) Graphite films (scale value is 10 µm).

a

b

Sensors 2014, 14

S3 Table S1. Comparison with other reported results.

Sensor/Device [Ref]

Max. Strain (%)

(a) Random MWCNT (b) Graphite Film sandwich in NR [present work]

620 (Limited by the substrate elongation limit) 246

(a) Aligned SWCNT (b) Random SWCNT film on PDMS [9]

280

Response Curve Type

Sensitivity

Sensitivity Relation with Strain

Close to linear

5–43

Linearly Increased with strain

Exponential

12–346

Increased with strain

Two linear regions

0.82–0.06

Durability and Repeatability

Delay Time (ms)

>400 cycles at 150%–500% strain (strain rate ~115% s−1) ~3,300 cycles at 200% strain

14 @ 2.5 Hz

-

-

Increased with strain 100 cycles at 80% strain

-

MWCNT network/PU [15]

403

Close to linear

4–69

Linearly Increased with strain

>1000 cycles at

Stretchable and flexible high-strain sensors made using carbon nanotubes and graphite films on natural rubber.

Conventional metallic strain sensors are flexible, but they can sustain maximum strains of only ~5%, so there is a need for sensors that can bear high...