Journal of Pharmaceutical and Biomedical Analysis 95 (2014) 207–212

Contents lists available at ScienceDirect

Journal of Pharmaceutical and Biomedical Analysis journal homepage: www.elsevier.com/locate/jpba

Simultaneous determination of bosentan and glimepiride in human plasma by ultra performance liquid chromatography tandem mass spectrometry and its application to a pharmacokinetic study Xiangjun Qiu a , Jianlong Zhao a , Zhe Wang b , Zhisheng Xu b,∗∗ , Ren-ai Xu c,∗ a

Medical College of Henan University of Science and Technology, Luoyang 471003, China The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325000, China c The First Affiliated Hospital of Wenzhou Medical University, Wenzhou 325000, China b

a r t i c l e

i n f o

Article history: Received 22 December 2013 Received in revised form 3 March 2014 Accepted 7 March 2014 Available online 16 March 2014 Keywords: Bosentan Glimepiride UPLC–MS/MS Human plasma Pharmacokinetic study

a b s t r a c t A sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method was developed to determine bosentan (BOS) and glimepiride (GPD) in human plasma simultaneously. Chromatographic separation was carried out on an Acquity UPLC BEH C18 column and mass spectrometric analysis was performed using a QTrap5500 mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 552.0 → 202.1 and m/z 491.2 → 125.9 were used to quantify BOS and GPD, respectively. This assay method has been fully validated in terms of selectivity, linearity, recovery and matrix effect, accuracy, precision and stability. The linearity of this method was found to be within the concentration range of 5–1000 ng/mL for BOS, and 2.5–500 ng/mL for GPD in human plasma. Only 1.5 min was needed for an analytical run. This assay was used to support a clinical study where multiple oral doses were administered to healthy Chinese subjects to investigate the pharmacokinetics of BOS and GPD. © 2014 Elsevier B.V. All rights reserved.

1. Introduction Bosentan (BOS) is a potent nonpeptide dual endothelin receptor antagonist (ERA) with affinity for both endothelin A and endothelin B receptors. It decreases both pulmonary and systemic vascular resistance, thereby increasing cardiac output without increasing the heart rate [1,2]. The single-dose pharmacokinetics of BOS have been described previously and were recently reviewed [3,4]. In brief, BOS shows dose-proportional pharmacokinetics up to single oral doses of 600 mg and an oral bioavailability of 50%. After intravenous administration of a 250 mg dose, a volume of distribution of 18 L and a clearance of 8.2 L/h were determined [5]. The apparent half-life after oral administration of 125 mg was 5.4 h [6]. BOS is extensively metabolized in the liver by CYP3A4 and CYP2C9 enzymes to give three metabolites namely, the hydroxybosentan (HYBOS), phenol metabolite and hydroxyl-phenol metabolite [7,8].

∗ Corresponding author. Tel.: +86 0577 55579705. ∗∗ Co-corresponding author. E-mail addresses: [email protected] (R.-a. Xu), [email protected] (Z. Xu). http://dx.doi.org/10.1016/j.jpba.2014.03.011 0731-7085/© 2014 Elsevier B.V. All rights reserved.

Several methods are reported for the determination of BOS in different biological matrices [9,10]. Glimepiride (GPD) is a third generation sulfonylurea type oral hypoglycemic agent, which is widely used in the treatment of type 2 diabetes [11,12]. In clinical trials, GPD is now considered to be a safe and effective hypoglycemic agent that does not lead to a gain in body weight [13]. GPD is almost completely bioavailable from the gastrointestinal tract [14] and metabolized by CYP2C9 to hydroxyglimepiride (M1), which is the rate-limiting step in its elimination process [15]. Several methods have been developed for the determination of GPD in human plasma by means of high performance liquid chromatography tandem mass spectrometry (HPLC–MS/MS) [16–20]. When BOS and GPD are used in combination in clinic, they may have many potential drug interactions as they are all CYP2C9 substrates. Even though various methods were reported in the literature for estimation of BOS and GPD individually or in combination with other drugs [21,22], no method had been reported for simultaneous estimation of these two drugs using ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS). Thus, it was essential to establish a high sensitive and more efficient assay for the simultaneous determination of BOS and GPD. In the present study, we developed an UPLC–MS/MS method for the simultaneous

208

X. Qiu et al. / Journal of Pharmaceutical and Biomedical Analysis 95 (2014) 207–212

flow and drying gas flow were 3.0 L/min and 15.0 L/min, respectively. Data acquiring and processing were performed using analyst software (version 1.5, AB Sciex). 2.3. Standard solutions, calibration standards and quality control (QC) sample

Fig. 1. The chemical structures and daughter scan ion spectra of the analytes and IS in the present study: (A) BOS; (B) GPD; and (C) losartan (IS).

determination of BOS and GPD using losartan as an internal standard. This new method has been fully validated in terms of specificity, linearity, matrix effect and recovery, accuracy, precision and stability. 2. Experimental 2.1. Chemicals and reagents BOS (purity 98.0%), GPD (purity 98.0%), and losartan (internal standard, IS, purity 98.0%) were obtained from Sigma (St. Louis, MO, USA). Formic acid was analytical grade and purchased from the Beijing Chemical Reagents Company (Beijing, China). Acetonitrile was of HPLC grade and was purchased from Merck Company (Darmstadt, Germany). HPLC grade water was obtained using a Milli Q system (Millipore, Bedford, USA). Blank plasma used in this study was supplied by the Second Affiliated Hospital of Wenzhou Medical University (Wenzhou, China). 2.2. UPLC–MS/MS conditions Liquid chromatography was performed on an Acquity ultra performance liquid chromatography (UPLC) unit (Waters Corp., Milford, MA) with an Acquity BEH C18 column (2.1 mm × 50 mm, 1.7 ␮m particle size) and inline 0.2 ␮m stainless steel frit filter (Waters Corp., Milford, USA). A gradient program was employed with the mobile phase, combining solvent A (0.1% formic acid in water) and solvent B (acetonitrile) as follows: 35% B (0–0.5 min), 35–80% B (0.5–1.0 min), 80–35% B (1.0–1.5 min). A subsequent re-equilibration time (1 min) should be performed before next injection. The flow rate was 0.45 mL/min and the injection volume was 10 ␮L. The column and sample temperature were maintained at 40 ◦ C and 4 ◦ C, respectively. An AB Sciex QTRAP 5500 triple quadruple mass spectrometer equipped with an electro-spray ionization (ESI) source (Toronto, Canada) was used for mass spectrometric detection. The quantitative analysis of BOS and GPD in human plasma was performed using multiple reaction monitoring (MRM) method. The dwell time was set to 300 ms for each MRM transition. The MRM transitions were m/z 552.0 → 202.1, m/z 491.2 → 125.9, and m/z 423.2 → 207.1 for BOS, GPD and IS, respectively (Fig. 1). The optimal MS parameters were as follows: capillary voltage 3.5 kV, desolvation line (DL) temperature 250 ◦ C, heat block temperature 400 ◦ C, nebulizing gas

The stock solutions of BOS and GPD used to make the calibration standards and quality control (QC) samples were prepared by dissolving 10 mg each compound in 10 mL methanol to obtain a concentration of 1.00 mg/mL of each compound. The stock solutions were further diluted with methanol to obtain working solutions at several concentration levels. Calibration standards and QC samples in plasma were prepared by diluting the corresponding working solutions with blank human plasma. Final concentrations of the calibration standards were 5, 10, 25, 50, 100, 250, 500 and 1000 ng/mL for BOS, and 2.5, 5, 10, 25, 50, 100, 250 and 500 ng/mL for GPD in human plasma, respectively. The concentrations of QC samples in plasma were 10, 200, and 800 ng/mL for BOS, and 5, 100, and 400 ng/mL for GPD, respectively. IS stock solution was made at an initial concentration of 1 mg/mL. The IS working solution (50 ng/mL) was made from the stock solution using acetonitrile for dilution. All stock solutions, working solutions, calibration standards and QCs were immediately stored at −80 ◦ C. 2.4. Sample preparation Before analysis, the plasma sample was thawed to room temperature. In a 1.5 mL centrifuge tube, an aliquot of 200 ␮L of the IS working solution (50 ng/mL in acetonitrile) was added to 100 ␮L of collected plasma sample. The tubes were vortex mixed for 1.0 min and spun in a centrifuge at 12,000 rmp for 10 min. The supernatant (10 ␮L) was injected into the UPLC–MS/MS system for analysis. 2.5. Method validation Before using this method to determinate BOS and GPD in clinical samples, the method was fully validated for specificity, linearity, sensitivity, precision, accuracy, recovery, matrix effect and stability according to the United States Food and Drug Administration (FDA) guidelines for the validation of a bioanalytical method [23]. A selectivity study is designed to investigate whether endogenous constituents and other substances existing in samples will interfere with the detection of analytes and IS. Selectivity was studied by comparing the chromatograms of six different batches of blank human plasma with the corresponding spiked plasma. Calibration curves were prepared according to Section 2.3. The linearity of each calibration curve was determined by plotting the peak area ratio (y) of analytes to IS versus the nominal concentration (x) of analytes with weighted (1/x2 ) least square linear regression. The lower limits of quantification (LLOQ) and limits of detection (LOD) were calculated based on signal-to-noise ratio of 10:1 and 3:1, respectively. LOD and LLOQ were defined as the analytes responses which yielded a signal to noise ratio of greater than 3 and 10, respectively, indicating that this method is sensitive for the quantitative evaluation of the analytes. The extraction recovery was evaluated by comparing peak areas obtained from extracted spiked samples with those of the postextracted spiked samples at corresponding concentrations. The extraction efficiency of the analytes was determined by analyzing six replicates of QC samples at three concentration levels. The matrix effect was evaluated by comparing the peak areas of the post-extracted spiked QC samples with those of corresponding standard solutions. The matrix effect of the analytes was determined by analyzing six plasma samples at three concentration levels. The extraction recovery and matrix effect of IS were

X. Qiu et al. / Journal of Pharmaceutical and Biomedical Analysis 95 (2014) 207–212

determined using the same procedure at a single concentration of 50 ng/mL. For the evaluation of intra-day precision and accuracy, six replicates QC samples were analyzed at three concentration levels on the same day. For the evaluation of inter-day precision and accuracy, three replicates of QC samples were analyzed at three concentration levels on six consecutive days. Precision was expressed as % relative standard deviation (RSD) and accuracy was expressed as % relative error (RE) between the measured and nominal value. The precision for QC samples was within 15%, and accuracy between −15 and 15%. The stability experiments were performed to evaluate the stability of the analytes in human plasma under the following conditions: short-term stability at room temperature for 24 h; long-term stability at −80 ◦ C for 30 days; three freeze (−80 ◦ C)–thaw (room temperature) cycles on consecutive days. The extracted QC samples kept in the autosampler at 4 ◦ C for 12 h were analyzed to evaluate post-preparation stability. All stability testing in plasma was determined by analyzing five replicates of QC samples at three concentration levels. The determined concentrations were compared with the nominal values.

209

2.7. Data analysis Plasma concentration vs. time profiles were analyzed using DAS software (Version 2.0, Medical University of Wenzhou, China) to estimate the type of compartment model and pharmacokinetic parameters. Data were expressed as mean ± SD.

3. Results and discussion 3.1. Method development and optimization The choice of mobile phase should be concerned based on the consideration of ionization efficiency before the analytes enter the MS/MS system in order to obtain nice resolution and high sensitivity. As for the choice of strong elution mobile phase, methanol and acetonitrile were considered as two candidates. Results showed that the responses of analytes with acetonitrile as the mobile phase were higher than those with methanol under ESI positive mode. To obtain the maximum sensitivity, we investigated the effects of pH with various mobile phases on the ionization efficiency. Both analytes and IS were found to have the highest response and the best peak shapes in the mobile phase containing 0.1% formic acid. The LC mobile phase was optimized with varying percentages of organic solvent and different modifiers in water to obtain high sensitivity. Analytes and IS were separated on an Acquity UPLC BEH C18 column with a gradient mobile phase consisting of acetonitrile and 0.1% formic acid. The whole separation of two analytes and IS was completed within only 1.5 min per sample. BOS, GPD and IS were eluted at about 0.57, 0.90 and 0.77 min, respectively. Sample preparation is a key step for accurate and reliable UPLC–MS/MS assays. Two kinds of sample treatment procedures were evaluated, including protein precipitation and liquid–liquid extraction (LLE). LLE could prepare purified and concentrated samples and improve the sensitivity and robustness of the assay. Protein precipitation was often used for the preparation of biological samples with the advantages of saving time and simplicity. In this work, two methods, including a protein precipitation procedure and acetic ether extraction, were investigated and compared. Because of a shorter sample preparation time, protein precipitation was employed as the extraction method.

2.6. Pharmacokinetic study The clinical protocol was approved by Medical Ethics Committee of the Second Affiliated Hospital of Wenzhou Medical University prior to the study. Ten volunteers were given written informed consent to participate in the study according to the principles of the Declaration of Helsinki. The volunteers who submitted the agreements to attend this project were medically examined for the pharmacokinetics study of BOS and GPD. The subjects were required to abstain from taking any other drug for 7 days prior to the start of test. They were also demanded not to smoke or drink alcohol for 24 h before the beginning of the study until its end. All volunteers were received an oral dose of 125 mg BOS and 2 mg GPD with 200 mL water. Blood samples (3 mL) were collected into heparinized tubes before and 0.5, 1, 1.5, 2, 2.5, 3, 4, 6, 8, 12, 24 and 48 h after oral administration. Blood samples were centrifuged at 4000 × g for 10 min and the plasma was separated and kept frozen at −80 ◦ C until analysis. Table 1 Recovery and matrix effect of BOS, GPD and internal standards (n = 6). Analytes

Concentration added (ng/mL)

Mean ± SD

RSD (%)

Mean ± SD

RSD (%)

BOS

10 200 800

90.67 ± 3.93 94.33 ± 1.75 94.67 ± 2.58

4.33 1.86 2.73

103.83 ± 7.00 94.67 ± 2.66 102.33 ± 5.01

6.74 2.81 4.89

GPD

5 100 400

87.50 ± 2.43 95.67 ± 2.25 90.83 ± 2.32

2.78 2.35 2.55

96.17 ± 4.26 97.18 ± 1.33 98.33 ± 4.84

4.43 1.37 4.93

50

92.36 ± 2.78

3.01

101.58 ± 5.42

5.34

IS

Recovery (%)

Matrix effect (%)

Table 2 Precision and accuracy of method for the determination of BOS and GPD in human plasma (n = 6). Analytes

Concentration added (ng/mL)

Intra-day precision (n = 6)

Inter-day precision (n = 6)

Mean ± SD

RSD (%)

RE (%)

Mean ± SD

RSD (%)

RE (%)

BOS

10 200 800

10.49 ± 0.86 205.50 ± 8.83 796.50 ± 15.57

8.21 4.29 1.95

4.85 2.75 −0.44

9.83 ± 0.63 208.17 ± 11.37 813.17 ± 25.95

6.38 5.46 3.19

−1.70 4.08 1.65

GPD

5 100 400

4.96 ± 0.18 97.33 ± 3.72 405.17 ± 11.27

3.62 3.83 2.78

−0.87 −2.67 1.29

5.15 ± 0.31 98.83 ± 5.31 406.83 ± 14.54

5.95 5.37 3.57

2.90 −1.17 1.71

1.10 −6.33 0.29 5.30 4.25 3.95 5.06 ± 0.27 93.66 ± 3.98 401.17 ± 15.84 1.83 −4.17 1.67 5.09 ± 0.40 95.83 ± 4.62 406.67 ± 17.20 −1.20 3.51 −1.08 7.36 6.07 3.36 4.96 ± 0.37 103.83 ± 6.31 399.17 ± 13.41 5 100 400 GPD

−0.77 3.83 −0.21

4.94 ± 0.33 103.50 ± 8.69 395.67 ± 13.22

6.75 8.31 3.34

7.82 4.82 4.23

RSD (%)

6.06 4.99 1.78 10.05 ± 0.61 192.50 ± 9.61 797.67 ± 14.21

Mean ± SD

0.33 −2.08 −0.77

RE (%)

10.03 ± 0.36 195.83 ± 11.97 806.17 ± 12.73

RSD (%) Mean ± SD RE (%)

−1.82 0.33 −0.27 4.77 5.72 3.61 9.82 ± 0.47 200.67 ± 11.48 797.83 ± 28.77 8.63 4.84 2.83 9.82 ± 0.85 192.67 ± 9.33 826.36 ± 23.40

RE (%) RSD (%) Mean ± SD

10 200 800 BOS

−1.80 −3.67 3.29

Mean ± SD

RSD (%)

3.60 6.11 1.58

−80 ◦ C, 30 days Three freeze–thaw Autosampler 4 ◦ C, 12 h Room temperature, 24 h Concentration added (ng/mL) Analytes

Table 3 Stability results of BOS and GPD in human plasma in different conditions (n = 5).

0.50 −3.75 −0.29

X. Qiu et al. / Journal of Pharmaceutical and Biomedical Analysis 95 (2014) 207–212

RE (%)

210

Fig. 2. Representative chromatograms of BOS, GPD and IS in human plasma samples. (A) A blank plasma sample; (B) a blank plasma sample spiked with BOS, GPD and IS; and (C) a plasma sample from a human 1.5 h after an oral co-administration of BOS and GPD.

3.2. Specificity Fig. 2 shows a typical chromatogram for the blank plasma (Fig. 2A), blank plasma spiked with analytes and IS (Fig. 2B), and human plasma obtained 1.5 h after oral administration of BOS and GPD (Fig. 2C). As shown in Fig. 2, there were no obvious endogenous interferences under the described chromatographic conditions.

3.3. Linearity and sensitivity The calibration curves were created by plotting the peak area ratios of the various analytes to internal standard versus nominal concentration of the analytes standards. Both calibration curves were regressed using a linear equation with a weighting factor of 1/x2 . The coefficient of correlation of all the calibration curves was more than 0.99. The typical regression equation of these curves was calculated as follows: BOS, y = (0.0103x + 2.54, r = 0.9995); GPD, y = (0.0149x + 0.0423, r = 0.9997). As shown, all the standard calibration curves showed good linearity within the range using least squares regression analysis. The LLOQ values were 3.0 ng/mL for BOS and 2.0 ng/mL for GPD, respectively. The LOD, yielded a signalnoise ratio of 3, were 1.0 ng/mL for BOS and 0.5 ng/mL for GPD, respectively.

X. Qiu et al. / Journal of Pharmaceutical and Biomedical Analysis 95 (2014) 207–212

211

Fig. 3. Plasma concentration versus time curves of BOS and GPD for ten healthy volunteers after a single oral dose of 125 mg BOS and 2 mg GPD.

3.4. Recovery and matrix effect The extraction recoveries and matrix effect of BOS and GPD ranged from 87.50 to 95.67% and 94.67 to 103.83%, respectively. The extraction recovery and matrix effect of IS were 92.36% and 101.58%, respectively. The detailed results are presented in Table 1. The matrix effect on the ionization of the analytes and IS was not obvious under these conditions. These data indicated that the sample preparation method was satisfactory and resulted in little appreciable matrix effect for the analytes and IS. 3.5. Precision and accuracy The intra- and inter-day precisions and accuracies of low, medium and high QC levels of the analytes are summarized in Table 2. The assay values for both intra- and inter-day were found to be within the accepted variable limits. The intra- and inter-day precisions of the analytes were within the range of 1.95–8.21% and 3.19–6.38%, respectively. The inter- and intra-day accuracies of the analytes were within the range of −2.67 to 4.85% and −1.70 to 4.08%, respectively. The results showed that the method was accurate and precise for the determination of the two analytes in human plasma. 3.6. Stability The stability of the two analytes in plasma was investigated by analyzing five replicates of QC samples at three concentration levels after short-term storage (room temperature, 24 h), at 4 ◦ C for 12 h after preparation, three freeze–thaw cycles, and long-term storage (−80 ◦ C, 30 days). The results were found to be within the assay variability limits (±15%). All results of stability tests are shown in Table 3. 3.7. Application of the method in a pharmacokinetic study The validated UPLC–MS/MS method was applied successfully in a single dose pharmacokinetic study of a combination dose of 125 mg BOS and 2 mg GPD in healthy Chinese subjects. The study was approved by the Ethics Committee of the Second Affiliated Hospital of Wenzhou Medical University. All subjects signed their informed consent form before the study. All the clinical samples were assayed by the validated method. The plasma samples with analyte concentrations above the upper limit of quantitation were diluted with blank human plasma. Representative chromatograms for BOS and GPD in real subject samples are shown in Fig. 2C. The mean plasma concentration time profiles of BOS and GPD in subjects are presented in Fig. 3. In addition, the main pharmacokinetic parameters are listed in Table 4.

Table 4 Pharmacokinetic parameters of BOS and GPD after oral administration 125 mg BOS and 2 mg GPD (n = 10). Parameter

BOS

t1/2 (h) Cmax (ng/mL) AUC0→∞ (ng/mL h) Vd (L/kg) CL (L/h) MRT (h)

8.59 886.33 6880.95 223.30 18.36 10.31

GPD ± ± ± ± ± ±

2.40 122.92 773.17 44.79 2.07 1.75

8.22 414.83 4452.06 5.32 0.46 9.94

± ± ± ± ± ±

2.50 20.45 539.78 1.67 0.06 1.63

4. Conclusions An UPLC–MS/MS method for the simultaneous determination of BOS and GPD in human plasma was developed and validated. To the best of our knowledge, this is the first report of the simultaneous determination of BOS and GPD levels in human plasma using an UPLC–MS/MS method. The method affords the sensitivity, accuracy and precision needed for quantitative measurements of BOS and GPD in human plasma. It was also successfully applied in a clinical pharmacokinetic study. References [1] L.J. Rubin, D.B. Badesch, R.J. Barst, N. Galie, C.M. Black, A. Keogh, T. Pulido, A. Frost, S. Roux, I. Leconte, M. Landzberg, G. Simonneau, Bosentan therapy for pulmonary arterial hypertension, N. Engl. J. Med. 346 (2002) 896–903. [2] H.W. Farber, J. Loscalzo, Pulmonary arterial hypertension, N. Engl. J. Med. 351 (2004) 1655–1665. [3] J. Dingemanse, P.L. van Giersbergen, Clinical pharmacology of bosentan, a dual endothelin receptor antagonist, Clin. Pharmacokinet. 43 (2004) 1089–1115. [4] P.L. van Giersbergen, J. Dingemanse, Comparative investigation of the pharmacokinetics of bosentan in Caucasian and Japanese healthy subjects, J. Clin. Pharmacol. 45 (2005) 42–47. [5] C. Weber, R. Schmitt, H. Birnboeck, G. Hopfgartner, S.P. van Marle, P.A. Peeters, J.H. Jonkman, C.R. Jones, Pharmacokinetics and pharmacodynamics of the endothelin-receptor antagonist bosentan in healthy human subjects, Clin. Pharmacol. Ther. 60 (1996) 124–137. [6] J. Dingemanse, F. Bodin, E. Weidekamm, K. Kutz, P. van Giersbergen, Influence of food intake and formulation on the pharmacokinetics and metabolism of bosentan, a dual endothelin receptor antagonist, J. Clin. Pharmacol. 42 (2002) 283–289. [7] L. Savale, R. Magnier, J. Le Pavec, X. Jais, D. Montani, D.S. O’Callaghan, M. Humbert, J. Dingemanse, G. Simonneau, O. Sitbon, Efficacy, safety and pharmacokinetics of bosentan in portopulmonary hypertension, Eur. Respir. J. 41 (2013) 96–103. [8] S.M. Markova, T. De Marco, N. Bendjilali, E.A. Kobashigawa, J. Mefford, J. Sodhi, H. Le, C. Zhang, J. Halladay, A.E. Rettie, C. Khojasteh, D. McGlothlin, A.H. Wu, W.C. Hsueh, J.S. Witte, J.B. Schwartz, D.L. Kroetz, Association of CYP2C9*2 with bosentan-induced liver injury, Clin. Pharmacol. Ther. 94 (2013) 678–686. [9] N. Ganz, M. Singrasa, L. Nicolas, M. Gutierrez, J. Dingemanse, W. Dobelin, M. Glinski, Development and validation of a fully automated online human dried blood spot analysis of bosentan and its metabolites using the Sample Card And Prep DBS System, J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. 885–886 (2012) 50–60. [10] J.M. Parekh, D.K. Shah, M. Sanyal, M. Yadav, P.S. Shrivastav, Development of an SPE-LC–MS/MS method for simultaneous quantification of bosentan and its active metabolite hydroxybosentan in human plasma to support a bioequivalence study, J. Pharm. Biomed. Anal. 70 (2012) 462–470.

212

X. Qiu et al. / Journal of Pharmaceutical and Biomedical Analysis 95 (2014) 207–212

[11] M. Massi-Benedetti, Glimepiride in type 2 diabetes mellitus: a review of the worldwide therapeutic experience, Clin. Ther. 25 (2003) 799–816. [12] B. Luna, M.N. Feinglos, Oral agents in the management of type 2 diabetes mellitus, Am. Fam. Physician 63 (2001) 1747–1756. [13] X.H. Guo, X.F. Lv, P. Han, X.Z. Zhang, H.Z. Yang, W.R. Duan, Y. Gao, Efficacy and safety of glimepiride as initial treatment in Chinese patients with Type 2 diabetes mellitus, Curr. Med. Res. Opin. 29 (2013) 169–174. [14] M. Badian, A. Korn, K.H. Lehr, V. Malerczyk, W. Waldhausl, Absolute bioavailability of glimepiride (Amaryl) after oral administration, Drug Metab. Drug Interact. 11 (1994) 331–339. [15] M. Niemi, I. Cascorbi, R. Timm, H.K. Kroemer, P.J. Neuvonen, K.T. Kivisto, Glyburide and glimepiride pharmacokinetics in subjects with different CYP2C9 genotypes, Clin. Pharmacol. Ther. 72 (2002) 326–332. [16] K. Noh, E. Kim, T. Jeong, M. Na, M.C. Baek, K.H. Liu, P.H. Park, B.S. Shin, W. Kang, Simultaneous determination of glimepiride and its metabolites in human plasma by liquid chromatography coupled to a tandem mass spectrometry, Arch. Pharm. Res. 34 (2011) 2073–2078. [17] L. Chakradhar, R. Kallem, A. Karthik, B.T. Sundari, S. Ramesh, R. Mullangi, N.R. Srinivas, A rapid and highly sensitive method for the determination of glimepiride in human plasma by liquid chromatography–electrospray ionization tandem mass spectrometry: application to a pre-clinical pharmacokinetic study, Biomed. Chromatogr. 22 (2008) 58–63.

[18] C. Pistos, M. Koutsopoulou, I. Panderi, Improved liquid chromatographic tandem mass spectrometric determination and pharmacokinetic study of glimepiride in human plasma, Biomed. Chromatogr. 19 (2005) 394–401. [19] H.J. Cho, S.Y. Lee, Y.G. Kim, S.Y. Oh, J.W. Kim, W. Huh, J.W. Ko, H.G. Kim, Effect of genetic polymorphisms on the pharmacokinetics and efficacy of glimepiride in a Korean population, Clin. Chim. Acta 412 (2011) 1831–1834. [20] H.W. Lee, M.S. Lim, J. Lee, M.Y. Jegal, D.W. Kim, W.K. Lee, I.J. Jang, J.G. Shin, Y.R. Yoon, Frequency of CYP2C9 variant alleles, including CYP2C9*13 in a Korean population and effect on glimepiride pharmacokinetics, J, Clin. Pharm. Ther. 37 (2012) 105–111. [21] Y. Yokoyama, M. Tomatsuri, H. Hayashi, K. Hirai, Y. Ono, Y. Yamada, K. Todoroki, T. Toyo’oka, H. Yamada, K. Itoh, Simultaneous microdetermination of bosentan, ambrisentan, sildenafil, and tadalafil in plasma using liquid chromatography/tandem mass spectrometry for pediatric patients with pulmonary arterial hypertension, J. Pharm. Biomed. Anal. 89 (2014) 227–232. [22] K.H. Shin, S.E. Kim, S.H. Yoon, J.Y. Cho, I.J. Jang, S.G. Shin, K.S. Yu, Pharmacokinetic comparison of a new sustained-release formulation of glimepiride/metformin 1/500 mg combination tablet and a sustained-release formulation of glimepiride/metformin 2/500 mg combination tablet in healthy Korean male volunteers: a randomized 2-sequence, 2-period, 2-treatment crossover study, Clin. Ther. 33 (2011) 1809–1818. [23] US Food and Drug Administration, Center for Drug Evaluation and Research, 2008.

Simultaneous determination of bosentan and glimepiride in human plasma by ultra performance liquid chromatography tandem mass spectrometry and its application to a pharmacokinetic study.

A sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed to determine bosentan (BOS) a...