Intraoperative Neurophysiological Monitoring for Spinal Cord Tumor Surgery: Comparison of Motor and Somatosensory Evoked Potentials According to Tumor Types.

To identify which combination of motor evoked potentials (MEPs) and somatosensory evoked potentials (SEPs) is most reliable for postoperative motor de...
830KB Sizes 1 Downloads 10 Views

Recommend Documents


Intraoperative monitoring of motor-evoked potentials for supratentorial tumor surgery.
The purpose of this study was to assess the feasibility and clinical efficacy of motor evoked potential (MEP) monitoring for supratentorial tumor surgery.

Neurophysiological assessment of spinal cord injuries in dogs using somatosensory and motor evoked potentials.
Somatosensory evoked potentials (SSEPs) and motor evoked potentials (MEPs) are non-invasive neurophysiological tests that reflect the functional integrity of sensory and motor pathways. Despite their extensive use and description in human medicine, r

Monitoring of Motor and Somatosensory Evoked Potentials During Spine Surgery: Intraoperative Changes and Postoperative Outcomes.
To evaluate whether the combination of muscle motor evoked potentials (mMEPs) and somatosensory evoked potentials (SEPs) measured during spinal surgery can predict immediate and permanent postoperative motor deficits.

Effects of Dexmedetomidine on motor- and somatosensory-evoked potentials in patients with thoracic spinal cord tumor: a randomized controlled trial.
We hypothesized that the addition of dexmedetomidine in a clinically relevant dose to propofol-remifentanil anesthesia regimen does not exert an adverse effect on motor-evoked potentials (MEP) and somatosensory-evoked potentials (SSEP) in adult patie

A new measure for monitoring intraoperative somatosensory evoked potentials.
To propose a new measure for effective monitoring of intraoperative somatosensory evoked potentials (SEP) and to validate the feasibility of this measure for evoked potentials (EP) and single trials with a retrospective data analysis study.

Intraoperative neurophysiological monitoring in spinal surgery.
Recently, many surgeons have been using intraoperative neurophysiological monitoring (IOM) in spinal surgery to reduce the incidence of postoperative neurological complications, including level of the spinal cord, cauda equina and nerve root. Several

Transoesophageal spinal cord stimulation for motor-evoked potentials monitoring: feasibility, safety and stability.
Specificity of transcranial motor-evoked potentials (MEPs) is low because amplitude fluctuation is common, which seems due to several technical and fundamental reasons including difficulty in electrodes positioning and fixation for transcranial stimu

Intraoperative Monitoring of Facial Nerve Motor-Evoked Potentials in Children.
To determine whether transcranial motor-evoked potential monitoring of the facial nerve (FNMEP) during eloquent tumor resection is feasible in children and can predict both immediate and postoperative facial nerve (FN) function.

An Electrode Configuration for Recording Muscle Motor Evoked Potentials in the Upper Extremities during Intraoperative Neurophysiological Monitoring.
The main aim of the present study is to examine the electrode configurations used to record the muscle motor evoked potential (mMEP) in the upper extremities during surgery with the goal of producing a high and stable mMEP signal, in particular among

Augmentation of motor evoked potentials using multi-train transcranial electrical stimulation in intraoperative neurophysiologic monitoring during spinal surgery.
Transcranial motor evoked potentials (TcMEPs) are widely used to monitor motor function during spinal surgery. Improvements in transcranial stimulation techniques and general anesthesia have made it possible to record reliable and reproducible potent