Accepted Manuscript Culture-Negative Prosthetic Joint Arthritis related to Coxiella burnetii Matthieu Million, MD, PhD Lucile Bellevegue, MD Anne-Sophie Labussiere, MD Michal Dekel, MD Tristan Ferry, MD, PhD Philippe Deroche, MD Cristina Socolovschi, MD, PhD Serge Camillerri, MD, PhD Didier Raoult, MD, PhD PII:

S0002-9343(14)00267-8

DOI:

10.1016/j.amjmed.2014.03.013

Reference:

AJM 12451

To appear in:

The American Journal of Medicine

Received Date: 24 January 2014 Revised Date:

10 March 2014

Accepted Date: 11 March 2014

Please cite this article as: Million M, Bellevegue L, Labussiere AS, Dekel M, Ferry T, Deroche P, Socolovschi C, Camillerri S, Raoult D, Culture-Negative Prosthetic Joint Arthritis related to Coxiella burnetii, The American Journal of Medicine (2014), doi: 10.1016/j.amjmed.2014.03.013. This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

ACCEPTED MANUSCRIPT Culture-Negative Prosthetic Joint Arthritis related to Coxiella burnetii

2

Matthieu MILLION, MD, PhD1, Lucile BELLEVEGUE, MD1, Anne-Sophie LABUSSIERE,

3

MD2, Michal DEKEL, MD3, Tristan FERRY, MD, PhD4, Philippe DEROCHE, MD5, Cristina

4

SOCOLOVSCHI, MD, PhD1, Serge CAMILLERRI, MD, PhD6, Didier RAOULT, MD,

5

PhD1#

6

RI PT

1

1. Aix-Marseille Université, Unité de Recherche sur les Maladies Infectieuses et

Tropicales Emergentes, UM63, CNRS 7278, IRD 198, INSERM 1095, Marseille,

8

France

10 11 12

2. Service de Maladies Infectieuses, Centre Hospitalier Jacques Coeur, Bourges, France 3. Infectious Diseases unit, Tel Aviv Sourasky Medical Center, affiliated with Sackler

M AN U

9

SC

7

Faculty of Medicine, Tel Aviv University, Ramat Aviv, Israel 4. Service de Maladies Infectieuses et Tropicales, Hospices Civils de Lyon, France; Centre Interrégional de Référence Rhône-Alpes Auvergne des Infections Ostéo-

14

articulaires complexes; Université Claude Bernard Lyon 1, France; Centre

15

International de Recherche en Infectiologie, CIRI, Inserm U1111, CNRS UMR5308,

16

ENS de Lyon, UCBL1, Lyon, France

TE D

13

5. Centre Orthopédique Médico-chirurgical, Dracy le Fort, France

18

6. Département de Médecine Nucléaire, Hôpital de La Timone, APHM, Université d’Aix-Marseille, Marseille, France

AC C

19

EP

17

20

Corresponding author: [email protected]

21

Alternate corresponding author: [email protected]

22

Telephone: (33) 491 38 55 17

23

Fax: (33) 491 83 03 90

24

Funding source: French National Referral Center for Q Fever

1

ACCEPTED MANUSCRIPT Conflict of interest statement: All authors (MM, LB, ASL, MD, TF, PD, CS, SC, DR) have

26

no conflict of interest to declare.

27

All authors had access to the data and a role in writing the manuscript;

28

Article type: Brief observation

29

Keywords: Culture negative prosthetic joint arthritis, Q fever, Coxiella burnetii

30

Running head: Q fever prosthetic joint arthritis

31

Abstract word count: 138

32

Body text word count: 1576

SC

RI PT

25

AC C

EP

TE D

M AN U

33

2

ACCEPTED MANUSCRIPT ABSTRACT

35

Background: The number of hip and knee arthroplasty procedures is steadily increasing as

36

life expectancy increases. Coxiella burnetii may be responsible for culture-negative prosthetic

37

joint arthritis and is associated with antibiotic failure and repeated surgeries. We report here

38

the first case series of Coxiella burnetii-related culture-negative prosthetic joint arthritis.

39

Methods: Cases were retrieved from the French National Referral center for Q fever.

40

Diagnosis was based on 18fluorodeoxyglucose positron emission tomography, serology,

41

broad-range polymerase chain reaction and Coxiella burnetii-specific polymerase chain

42

reaction.

43

Results: Four cases of Coxiella burnetii-related culture-negative prosthetic joint arthritis were

44

found. Standard bacteriological procedures would have missed the diagnosis in all cases.

45

Etiological diagnosis improved the outcome in all but one case.

46

Conclusions and Relevance: A systematic, comprehensive diagnostic strategy should be

47

used in culture-negative prosthetic joint arthritis, including testing for Coxiella burnetii in

48

endemic areas.

TE D

M AN U

SC

RI PT

34

49

AC C

EP

50

3

ACCEPTED MANUSCRIPT 51

Prosthetic-joint arthritis, defined as an inflammation of the periprosthetic tissues, has a significant impact on the quality of life. Prosthetic-joint arthritis affects approximately 2% of

53

individuals with primary arthroplasty and up to 20% of revision procedures. Prosthetic-joint

54

arthritis represents a major public health issue. Approximately 800,000 Americans have a hip

55

or knee replaced each year and this number is steadily increasing as life expectancy increases.

56

Late prosthetic-joint arthritis is distinguished from early postoperative prosthetic-joint

57

arthritis, which is represented mainly by infections acquired during surgery. In our

58

experience, late prosthetic-joint arthritis occurs in conditions strikingly similar to late

59

endocarditis: both may be linked to a hematogenous infection or to non-infectious diseases

60

(gout, aseptic loosening or crystal-induced joint disease for prosthetic-joint arthritis; auto-

61

immunity, pork allergy or paraneoplastic disease have been reported for endocarditis)1, 2.

SC

M AN U

62

RI PT

52

Both culture-negative prosthetic-joint arthritis and blood culture negative endocarditis have been associated with treatment failure despite multiple antibiotic regimens and

64

surgeries1, 3, 4. Indeed, fastidious or zoonotic bacteria and fungi are responsible for infections

65

with negative standard bacteriological culture and are usually not eradicated by the antibiotics

66

prescribed empirically in culture negative prosthetic-joint arthritis or blood culture-negative

67

endocarditis, such as vancomycin. We (DR) previously collaborated with the first Coxiella

68

burnetii prosthetic-joint arthritis report3, and we report here four additional cases from the

69

French national referral center for Q fever. The diagnosis dramatically improved the outcome

70

in all cases but one and led us to propose a comprehensive diagnostic strategy in this context,

71

including new criteria to define C. burnetii-related prosthetic joint arthritis (Table 1).

72

AC C

EP

TE D

63

A 60-year-old woman was admitted on June 2012 for left hip pain. Her medical

73

history included a left total hip arthroplasty in 2007. Clinical examination revealed a low-

74

grade fever. A pseudo-tumor was observed by magnetic resonance imaging around the

75

prosthesis. A one-stage hip revision with resection of the pseudotumor and change of the

4

ACCEPTED MANUSCRIPT prosthesis was performed in October 2012. Standard bacteriological cultures of intraoperative

77

samples yielded small, curved, Gram-negative bacilli (consistent with C. burnetii) with no

78

growth. C. burnetii was identified on the periprosthetic material using 16S rRNA

79

amplification and specific quantitative polymerase chain reaction analysis (IS30 and IS1111

80

genes). Histopathology confirmed an inflammatory pseudotumor, previously described with Q

81

fever. Serological results were phase I IgG, IgM and IgA at 800, 0, and 0, and phase II at

82

1600, 0, and 0, respectively, suggesting a persistent infection. This case was considered as a

83

definite Q fever prosthetic-joint arthritis based on the proposed criteria (A1B1C3).

84

Disappearance of fever and pain and good serological outcome at 12 months while on

85

doxycycline and hydroxychloroquine also support the diagnosis.

SC

M AN U

86

RI PT

76

In October 2012, an 82-year-old man presented with a new C. burnetii serological increase 3 years after acute Q fever without any symptoms. His past medical history included

88

a total hip arthroplasty in 1992 with a revision in 2001. An 18fluorodeoxyglucose positron

89

emission tomography showed right hip prosthetic joint hypermetabolism (Figure 1). Standard

90

aerobic and anaerobic cultures of joint fluid aspirate were negative. A C. burnetii-specific

91

quantitative polymerase chain reaction analysis was positive in two different joint aspirate

92

samples and for two different genes (IS30 and IS1111). This case was considered as a definite

93

Q fever prosthetic joint arthritis (A1B1C3), although the patient was asymptomatic and had

94

no joint pain at the Q fever prosthetic joint arthritis diagnosis. A good serological outcome

95

while on doxycycline and hydroxychloroquine also supports the diagnosis.

EP

AC C

96

TE D

87

In November 2012, an 84-year-old man was admitted complaining of fever and right

97

hip pain. The patient’s medical history included a right total hip arthroplasty 27 years before.

98

Physical examination revealed right hip pain with irradiation to the knee. Transthoracic

99

echocardiography was normal. Blood cultures were negative. C. burnetii serology results

100

were phase I IgG, IgM and IgA at 1600, 0 and 0, and phase II IgG, IgM and IgA at 3200, 0

5

ACCEPTED MANUSCRIPT and 0, respectively. Phase I IgG rapidly increased to 6400, suggesting a persistent and active

102

infection. A positron emission tomography found an uptake at the bone-prosthesis interface

103

with exclusion of the head and the tip associated with hypermetabolism of the right iliac

104

lymph nodes. No surgery or joint aspiration could be performed because of surgical contra-

105

indication due to the condition of the patient and in the absence of collection at the computed

106

tomography scan. This case was considered a definite Q fever prosthetic-joint arthritis

107

(A0B2C3). Disappearance of pain and positron emission tomography scan anomalies while

108

on doxycycline and hydroxychloroquine also support the diagnosis.

SC

109

RI PT

101

In summer 2013, a 63-year-old woman was admitted for progressive left hip pain without fever. She had a history of left total hip arthroplasty in 1992, revised in 2002, and

111

rheumatoid arthritis treated with methotrexate and adalimumab. Symptoms appeared three

112

weeks after contact with sheep in Morocco. A periprosthetic collection was identified by a

113

computed tomography scan. Liquid joint analysis revealed pus without bacterial growth,

114

whereas the patient did not receive antibiotics. C. burnetii was identified using 16S rRNA

115

amplification. Serology found phase I IgG at 800 increasing to 1600 two months later,

116

without IgM or IgA. The joint prosthesis was removed and replaced by a cement spacer.

117

Bacterial cultures remained negative, and histopathology revealed non-specific bone and

118

synovial inflammation. C. burnetii was identified on the periprosthetic material using 16S

119

rRNA amplification and specific quantitative PCR analysis (IS30 and IS1111 genes) on four

120

different periprosthetic samples. This case was considered definite Q fever prosthetic-joint

121

arthritis (A1B1C3). Despite prolonged long-term doxycycline and hydroxychloroquine

122

therapy, the outcome was unfavorable, and spacer explantation was required with positive

123

polymerase chain reaction on spacer at 4 months of treatment. No other infection was

124

diagnosed.

AC C

EP

TE D

M AN U

110

6

ACCEPTED MANUSCRIPT 125

The 4 cases of prosthetic joint arthritis described here were related to C. burnetii because the bacterium was identified by detecting two or three different genes in different

127

samples and the serology suggested a persistent C. burnetii infection in all cases. Standard

128

cultures of joint samples were negative in the 3 patients in whom it was performed, although

129

direct examination was positive and consistent with C. burnetii in one case. The new increase

130

of phase I IgG 3 years after primary infection in one case and the rapid serological increase in

131

another case also suggest an active infection. The 4 cases were associated with radiological or

132

positron emission tomography scan anomalies. In two cases, the positron emission

133

tomography scan identified an uptake at the bone-prosthesis interface, which is the best

134

criterion for infection. The association with a hypermetabolism of iliac lymph nodes in one

135

case also suggests an active infection. In one case, joint aspiration guided by computed

136

tomography scan could not be achieved due to the absence of collection. Indeed, absence of

137

inflammatory exudate is a classical feature of C. burnetii. An inflammatory pseudotumor is

138

characteristic of Q fever and has been previously described in the lung and spleen. The good

139

clinical, serological and positron emission tomography scan outcome after specific treatment

140

in 3 out of 4 cases also suggests that C. burnetii was the bacteria responsible for the infection.

141

Therapeutic failure in the last case remained unexplained and may be linked to a resistant

142

strain, previously reported only once in endocarditis, or to the underlying disease (rheumatoid

143

arthritis with immunosuppressive treatment).

SC

M AN U

TE D

EP

AC C

144

RI PT

126

Culture-negative prosthetic joint arthritis accounts for 10% of prosthetic joint arthritis,

145

whereas blood culture-negative endocarditis accounts for 20% of endocarditis. Of the culture

146

negative-prosthetic joint arthritis cases, half are related to the administration of antibiotics

147

before the microbiological analysis. Biofilm bacteria on the surface of the removed implants

148

are best identified after prosthesis sonication, and recent molecular studies also suggested that

149

non-cultivable microorganisms could play a role5. We found 301 documented cases of culture

7

ACCEPTED MANUSCRIPT negative prosthetic joint arthritis in the literature, with 98% related to hip or knee articulations

151

(hand 3, shoulder 2 and elbow 1 case each). Of these documented cases, 46% were related to

152

fungi, 43% to mycobacteria and 11% to bacteria. Excluding 2 cases related to antibiotics, we

153

found 31 culture-negative prosthetic arthritis related to bacteria, including Brucella (11 cases),

154

C. burnetii3 (5 cases, including the 4 cases reported here and 1 previously reported3),

155

Streptococcus (3), Tropheryma whipplei4 (2), Staphylococcus (2), Propionibacterium acnes

156

(2) and Listeria monocytogenes (1). Surprisingly, this etiological spectrum is similar to that of

157

blood culture negative endocarditis1, except that Bartonella and Chlamydia prosthetic joint

158

infections were not present. In addition, the different regional prevalence of zoonotic agents

159

must be taken into account. Human cases of Q fever are ubiquitous around the world outside

160

of New Zealand but prevalence is particularly increased close to rural areas. In comparison,

161

brucellosis is uncommon or absent in most European countries and Australia.

SC

M AN U

162

RI PT

150

All patients with suspected prosthetic joint arthritis should have synovial fluid and/or periprosthetic tissue sent for standard microbiological culture and analysis for uric acid

164

crystals. If the prosthesis is removed, ultrasonication to dislodge adherent bacteria followed

165

by aerobic and anaerobic microbiological culture should be performed. If the microbiological

166

standard culture is negative, the patient should undergo a systematic diagnostic procedure for

167

culture-negative prosthetic joint arthritis, including C. burnetii and Brucella serology.

168

Mycobacterial direct examination and culture as well as conventional broad-range polymerase

169

chain reaction5 and fungal-specific polymerase chain reaction should be performed on the

170

joint sample.

171

AC C

EP

TE D

163

Here, we report 4 new cases of prosthetic joint arthritis related to C. burnetii with a

172

negative standard bacteriological culture in all 3 cases in which it was performed. As in blood

173

culture-negative endocarditis, a systematic comprehensive diagnostic strategy should be

8

ACCEPTED MANUSCRIPT 174

applied in culture-negative prosthetic joint arthritis, including Coxiella burnetii testing in

175

endemic areas.

AC C

EP

TE D

M AN U

SC

RI PT

176

9

ACCEPTED MANUSCRIPT Signed patient consent forms have been obtained for all patients.

178

Acknowledgements: We thank all patients for agreeing to the publication of their cases.

179

Funding: This work was supported by the French National Referral Center for Q Fever.

180

Conflict of interest: All the authors (MM, LB, ASL, MD, TF, PD, CS, SC, DR) declare that

181

they have no conflicts of interest.

RI PT

177

182 183

AC C

EP

TE D

M AN U

SC

184

10

ACCEPTED MANUSCRIPT References

185 186 187

(1)

Fournier PE, Thuny F, Richet H et al. Comprehensive diagnostic strategy for

blood culture-negative endocarditis: a prospective study of 819 new cases. Clin Infect Dis

189

2010;51(2):131-140.

191 192

(2)

Zimmerli W, Trampuz A, Ochsner PE. Prosthetic-joint infections. N Engl J

Med 2004;351(16):1645-1654. (3)

Tande AJ, Cunningham SA, Raoult D, Sim FH, Berbari EF, Patel R. A case of

SC

190

RI PT

188

Q fever prosthetic joint infection and description of an assay for detection of Coxiella

194

burnetii. J Clin Microbiol 2013;51(1):66-69.

196 197 198 199 200

(4)

Cremniter J, Bauer T, Lortat-Jacob A et al. Prosthetic hip infection caused by

Tropheryma whipplei. J Clin Microbiol 2008;46(4):1556-1557. (5)

Levy PY, Fournier PE, Fenollar F, Raoult D. Systematic PCR Detection in

Culture-negative Osteoarticular Infections. Am J Med 2013;126(12):1143-33. (6)

TE D

195

M AN U

193

Raoult D. Chronic Q fever: expert opinion versus literature analysis and

consensus. J Infect 2012;65(2):102-108.

AC C

202

EP

201

11

ACCEPTED MANUSCRIPT Figure legends

204

Figure 1. PET scan of a case of Q fever Prosthetic Joint Arthritis

205

A F18 fluorodeoxyglucose positron emission tomography / computed tomography scan reveals

206

an increased radiotracer accumulation in the right hip prosthesis (patient 2). The uptake at the

207

bone-prosthesis interface with exclusion of the head and tip, as found in this patient, is

208

considered the best criterion for infection, with 92% sensitivity and 97% specificity. This

209

patient had an acute episode of Q fever 3 years previously with a new recent serological

210

increase (phase I IgG increasing from 800 to 3200 and phase I IgA increasing from 50 to 100

211

without IgM). C. burnetii-specific quantitative polymerase chain reaction analysis was

212

positive on two different joint aspirate samples and for two different genes (IS30 and IS1111),

213

confirming the diagnosis.

AC C

EP

TE D

M AN U

SC

RI PT

203

12

ACCEPTED MANUSCRIPT Table 1. Definition of Coxiella burnetii-related Prosthetic Joint Arthritis (adapted from Raoult et al1). A. Definite criterion Positive culture, polymerase chain reaction, or immunochemistry of a periprosthetic

RI PT

biopsy or joint aspirate. B. Major criteria Microbiology:

Positive culture or polymerase chain reaction of the blood



Positive Coxiella burnetii serology with IgGI antibodies ≥ 6400

M AN U

Evidence of prosthetic involvement:

SC



Computerized tomography scan or magnetic resonance imaging positive for prosthetic infection: collection or pseudotumor of the prosthesis Positron emission tomography scan or indium leucoscan showing a specific

TE D

prosthetic hyperfixation consistent with infection1 C. Minor criteria

Presence of a joint prosthesis (indispensable criteria)

AC C

Joint pain

EP

Fever, temperature > 38° C

Serological evidence: Positive Coxiella burnetii serology with IgGI antibodies ≥ 800 and < 6400

Diagnosis definite 1) 1A criterion 2) 2B criteria

3) 1B criterion and 3C criteria (including 1 microbiology evidence, and presence of a joint prosthesis)

ACCEPTED MANUSCRIPT Diagnosis possible 1) 1B criterion, 2C criteria (including 1 microbiology evidence and presence of a joint prosthesis)

1

RI PT

2) 3C criteria (including positive serology and presence of a joint prosthesis)

For the F18 fluorodeoxyglucose positron emission tomography scan, the uptake at the bone-

prosthesis interface with exclusion of the head and tip is considered the best criterion for

AC C

EP

TE D

M AN U

SC

infection, with 92% sensitivity and 97% specificity.

ACCEPTED MANUSCRIPT Reference (1) Raoult D. Chronic Q fever: expert opinion versus literature analysis and consensus. J

AC C

EP

TE D

M AN U

SC

RI PT

Infect 2012;65(2):102-108.

AC C

EP

TE D

M AN U

SC

RI PT

ACCEPTED MANUSCRIPT

ACCEPTED MANUSCRIPT Clinical significance Word count: 67 •

Prosthetic joint arthritis involves 2% of individuals with a joint prosthesis, is associated with significant morbidity and will represent a major public health issue in the coming decades Coxiella burnetii may be responsible for culture-negative prosthetic joint arthritis and is

RI PT



associated with antibiotic failure and repeated surgeries when undiagnosed

Prosthetic joint infection related to Coxiella burnetii will remain undiagnosed if not suspected

EP

TE D

M AN U

SC

systematically particularly in endemic areas

AC C



Culture-negative prosthetic joint arthritis related to Coxiella burnetii.

The number of hip and knee arthroplasty procedures is steadily increasing as life expectancy increases. Coxiella burnetii may be responsible for cultu...
754KB Sizes 3 Downloads 3 Views