crossmark
AUTHOR CORRECTION
Correction for Okabayashi et al., Detection of Chikungunya Virus Antigen by a Novel Rapid Immunochromatographic Test Tamaki Okabayashi,a,f Tadahiro Sasaki,f Promsin Masrinoul,a,d Nantarat Chantawat,a Sutee Yoksan,d Narong Nitatpattana,d Sarunyou Chusri,e Ronald E. Morales Vargas,b Marc Grandadam,g Paul T. Brey,g Soegeng Soegijanto,h Kris Cahyo Mulyantno,h Siti Churrotin,h Tomohiro Kotaki,h,i Oumar Faye,j Ousmane Faye,j Abdourahmane Sow,j Amadou Alpha Sall,j Orapim Puiprom,a Panjaporn Chaichana,a Takeshi Kurosu,f Seiji Kato,k Mieko Kosaka,k,l Pongrama Ramasoota,c Kazuyoshi Ikutaf Mahidol-Osaka Center for Infectious Diseases (MOCID), Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailanda; Department of Medical Entomology, Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailandb; Center of Excellence for Antibody Research, Faculty of Tropical Medicine, Mahidol University, Bangkok, Thailandc; Center for Vaccine Development, Mahidol University, Nakhon Pathom, Thailandd; Division of Infectious Disease, Department of Internal Medicine, Faculty of Medicine, Prince of Songkla University, Hat Yai, Thailande; Department of Virology, Research Institute for Microbial Diseases, Osaka University, Osaka, Japanf; Institute Pasteur du Laos, Vientiane, Lao People’s Democratic Republicg; Indonesia-Japan Collaboration Research Center for Emerging and Re-emerging Infectious Diseases, Institute of Tropical Diseases, Airlangga University, Surabaya, Indonesiah; Center for Infectious Diseases, Kobe University Graduate School of Medicine, Hyogo, Japani; Arboviruses and Viral Hemorrhagic Fever Unit, Institute Pasteur de Dakar, Dakar, Senegalj; Alfresa Pharma Corporation, Osaka, Japank; Arkray Incorporated, Kyoto, Japanl
Volume 53, no. 2, p. 382–388, 2015. Page 384, Fig. 1: Incorrect images were mistakenly placed in the second (Thai), fourth (S27), and sixth (SV) columns in the row labeled “Alphavirus Antibody.” The figure should appear as shown below.
Page 385, Table 2: Several values in the “IgM ELISA result” section are incorrect; the section should appear as shown below. According to these value replacements, the specificities for the IgM ELISA were lower than those given in the original publication. The results for the IC test are not affected by this correction.
Citation Okabayashi T, Sasaki T, Masrinoul P, Chantawat N, Yoksan S, Nitatpattana N, Chusri S, Morales Vargas RE, Grandadam M, Brey PT, Soegijanto S, Mulyantno KC, Churrotin S, Kotaki T, Faye O, Faye O, Sow A, Sall AA, Puiprom O, Chaichana P, Kurosu T, Kato S, Kosaka M, Ramasoota P, Ikuta K. 2016. Correction for Okabayashi et al., Detection of chikungunya virus antigen by a novel rapid immunochromatographic test. J Clin Microbiol 54:1173–1174. doi:10.1128/JCM.03073-15. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
April 2016 Volume 54 Number 4
Journal of Clinical Microbiology
jcm.asm.org
1173
Author Correction
IgM ELISA result Country
No. of patients
Genotype
RNA result (n)
No. positive
No. negative
Sensitivity (%)
Specificity (%)
OAAa
Thailand
50
ECSAb
Positive (34) Negative (16)
7 11
27 5
20.6
31.3
24.0
Laos
54
ECSA
Positive (34) Negative (20)
2 3
32 17
5.9
85.0
35.2
Indonesia
2
Asian
Positive (2) Negative (0)
0 0
2 0
Senegal
6
West African
Positive (6) Negative (0)
0 0
6 0
Total
112
Positive (76) Negative (36)
9 14
67 22
11.8
61.1
27.7
1174
jcm.asm.org
Journal of Clinical Microbiology
April 2016 Volume 54 Number 4