Original Article

Automated hearing screening for preschool children

J Med Screen 2014, Vol. 21(2) 71–75 ! The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav DOI: 10.1177/0969141314528322 msc.sagepub.com

Anna Chi Shan Kam1,2, Lawrence Kwok Chang Li1, Kammy Ngan Kam Yeung1, Wenjin Wu3,4, Zhiwu Huang3,4, Hao Wu3,4 and Michael Chi Fai Tong1,2

Abstract Objectives: To establish the reliability and validity of an automated hearing screening test system for preschoolers and to investigate the risk factors for hearing loss. Methods: The study used a cross-sectional design in a comparative study of subjects. The automated hearing screening test was performed in 6231 preschoolers (3–7 years old) from 41 kindergartens in Shanghai, China. Sensitivity and specificity of the automated test were investigated with subjects who failed the screening test and a group of control subjects. Results: Six hundred and forty-seven children were referred for diagnostic audiological assessment after the automated puretone screening test. Using the conventional pure-tone audiometry as the ‘‘gold standard,’’ the sensitivity and specificity of the automated hearing screening test increased from 0.33 and 0.15 in the youngest age group to 0.95 and 1.00 in the oldest age group, respectively. There was no statistically significant gender effect, but there was an age effect (2 ¼ 22.96, p < 0.01). In the univariate analysis of 104 cases and 201 controls, significantly elevated odds ratios (OR) for hearing loss were correlated with universal newborn hearing screening test results (OR ¼ 28.15, p < 0.01), parental suspicion of hearing loss (OR ¼ 10.10, p < 0.05), and attendance at preschool before the age of five (OR ¼ 0.51, p < 0.05). Conclusions: The results suggest that the automated hearing screening test system can be used in screening programmes for preschoolers aged older than five years. Keywords automated, hearing screening, preschool children Date received: 2 January 2014; accepted: 26 February 2014

Introduction Early identification of children with hearing loss has been made possible with the implementation of newborn hearing screening tests. Continued screening for preschooland school-aged children can help to identify children with progressive or late-onset hearing impairment. The American Academy of Pediatrics recommends newborn hearing screening and periodic hearing screening for every child through adolescence.1 Among the available audiometric screening tools, such as the pure tone test, otoacoustic emission test (OAE), auditory brainstem response (ABR), tympanometry, and questionnaires, the pure tone test has been considered the gold standard in hearing screening for children.2–8 However, young preschool children may have difficulty in understanding the instructions of the pure-tone test and their attention spans may be too limited to complete the test.9–10 We used a previously developed automated pure-tone hearing test system11 composed of a tablet computer and a pair of noise-cancelling headphones that help to control the ambient noise levels common in schools. The hearing test is incorporated into an interactive listening game

designed to engage children’s attention. A previous study showed that the automated test could be implemented in school hearing screening programmes in places where professional audiological support is scarce.11 This study further investigates the validity and feasibility of using the system to conduct hearing screening programmes in kindergartens.

1 Department of Otorhinolaryngology, Head and Neck Surgery, Chinese University of Hong Kong 2 Institute of Human Communicative Research, Chinese University of Hong Kong 3 Department of Otolaryngology Head and Neck Surgery, Xinhua Hospital, Shanghai Jiaotong University School of Medicine 4 Ear Institute, Shanghai Jiaotong University School of Medicine

Corresponding author: Michael Chi Fai Tong, Department of Otorhinolaryngology, Head and Neck Surgery, Chinese University of Hong Kong. Email: [email protected]

Downloaded from msc.sagepub.com at The University of Hong Kong Libraries on May 7, 2015

72

Journal of Medical Screening 21(2)

Subjects and methods Subjects The subjects were children recruited from 41 kindergartens in Yangpu District, Shanghai, one of China’s urban districts. All 96 kindergartens in the district were invited to join the study; 41 chose to participate. The subjects were recruited on a voluntary basis and written consent was obtained from parents before the testing.

Equipment and test setting Automated hearing screening test. The automated hearing screening test was developed and written in Java. The hearing test was administered on a tablet computer (Samsung Galaxy Tab 7.7) with headphones (a pair of Bose QuietComfortÕ 15 Acoustic Noise CancellingÕ headphones) as the transducer for testing. Details of the automated hearing screening system, including the calibration of the system and the adapted screening procedures, have been previously described.11 The system tests three frequencies (1000, 2000 and 4000 Hz) as recommended in the most commonly adopted testing guidelines.2 Continuous pure-tones for each of the test frequencies were first presented on the right side. If a threshold higher than 30 dB HL was obtained at any tested frequency in either ear, the test result would be regarded as ‘‘initial refer’’, and an immediate rescreen with the same test system would be done to confirm the result. If the subject passed the rescreen, the overall result would be regarded as ‘‘pass’’. Otherwise, the test result would be regarded as ‘‘refer’’, indicating that the subject should be referred for professional assessment. Nurses who had received two hours of training on the use of the automated screening system acted as facilitators and monitored the automated testing. The tests were conducted in quiet rooms in the kindergartens, with an ambient noise level ranging from 40 to 51 dBA. During the conditioning phase, some introductory pictures were displayed on the tablet while the facilitator explained the test to the subject and ensured that they understood the task. During the testing phase, no cues were provided and only neutral acknowledgements (such as nodding and praising for the child’s effort) from the facilitator were allowed. Diagnostic audiological assessment. Children who failed the automated rescreening were subsequently referred for a diagnostic audiological assessment, carried out in sound booths in the Shanghai Children’s Hearing and Speech Centre. Five percent of the children who had passed the automated screening test were also referred for a diagnostic assessment as controls. The diagnostic assessment included an otoscopy, tympanometry, distortion product otoacoustic emissions test, and standard pure-tone audiometry or play audiometry. Air-conduction thresholds were obtained at 0.25, 0.5, 1. 2. 4 and 8 kHz according to ANSI S3.6-2004 testing guidelines.12 Bone-conduction thresholds at 0.5, 1, 2 and 4 kHz

were also obtained. The equipment used was a Madsen Conera clinical audiometer with Telephonics TDH-39 headphones, a GSI Tympstar middle ear analyzer and a Madsen Capella OAE system. The parents of the subjects who underwent the diagnostic test were asked to fill in a questionnaire asking about medical history and other risk factors for hearing loss. Follow-up arrangement. Hearing screening reports on all of the tested children were provided to the schools and parents within one week of the screening. Further audiological and medical follow-up procedures were recommended according to the results of the diagnostic test.

Results Subject demographics The study included 6231 participating children, 3250 boys and 2981 girls, aged between 3 years and 6 years 11 months (mean ¼ 5.03, standard deviation [SD] ¼ 0.09). Table 1 shows the demographic data of the subjects.

Referral rate The overall referral rate of the automated hearing screening test was 10.38% (647/6231). There was no statistically significant gender effect (2 ¼ 0.05, p > 0.05, d.f. ¼ 1), but there was a significant age effect (2 ¼ 4.87, p < 0.05, d.f. ¼ 3) on the referral rates. As shown in Table 2, the referral rate decreased as the age of the subjects increased. The percentage of incomplete cases also decreased with the increase in age.

Diagnostic test results Of 959 children referred for a diagnostic assessment, 647 had failed the automated hearing rescreening test

Table 1. Demographic data of subjects who attended the screening and diagnostic test. Number of children (%) Diagnostic test

Age

Screening test (n ¼ 6231)

Refer (n ¼ 432)

Control (n ¼ 284)

3y–3y11m 4y–4y11m 5y–5y11m 6y–6y11m

460 2320 2823 628

73 220 119 20

18 110 118 38

Male Female

3250 (52.16) 2981 (47.84)

(7.38) (37.23) (45.45) (10.08)

(16.90) (50.93) (27.55) (4.63)

(6.33) (38.73) (41.55) (13.38)

Gender

y ¼ years, m ¼ months.

Downloaded from msc.sagepub.com at The University of Hong Kong Libraries on May 7, 2015

194 (55.4) 240 (44.6)

139 (48.94) 145 (51.06)

Kam et al.

73

Table 2. Screening results for different age groups.

Age

Number of passes (%)

Number of incompletes (%)

Number of referrals (%) (incomplete cases included)

3y–3y11m 4y–4y11m 5y–5y11m 6y–6y11m

352 2009 2624 599

11 23 11 0

108 (23.48) 312 (13.44) 199 (7.05) 29 (4.62)

(76.52) (86.59) (92.95) (95.38)

(2.39) (0.99) (0.39) (0.00)

y ¼ years, m ¼ months.

Table 3. Sensitivity and specificity of the automated hearing screening test in different age groups. Age

Sensitivity

95% CI

Specificity

95% CI

3y–3y11m 4y–4y11m 5y–5y11m 6y–6y11m

0.33 0.54 0.92 0.95

0.09–0.69 0.37–0.71 0.84–0.96 0.74–1.00

0.15 0.32 0.79 1.00

0.08–0.25 0.27–0.38 0.71–0.85 0.88–1.00

y ¼ years, m ¼ months.

Table 4. The results of the univariate analysis of the studied factors. Factor

Odds ratio

95% CI

Gender (male/female) UNHS result (pass/fail) Family history with hearing loss (Yes/No) History of hospitalization (Yes/No) Chronic disease (Yes/No) Allergies (Yes/No) Nasal problem (Yes/No) Head trauma (Yes/No) Snoring (Yes/No) Ototoxicity (Yes/No) History of otitis media (Yes/No) Suspected hearing loss (Yes/No) Serious illness (Yes/No) Preschool before 5 (Yes/No) Passive smoking (Yes/No) Language delay (Yes/No)

1.44 28.15** 1.30 1.46 2.96 0.78 0.96 2.64 0.96 1.94 1.55 10.10* 3.92 0.51* 1.08 1.16

0.89–2.31 3.66–216.57 0.36–4.71 0.32–6.66 0.49–17.97 0.45–1.35 0.40–2.33 0.58–12.02 0.46–2.01 0.12–31.36 0.72–3.32 1.16–87.63 0.35–43.76 0.27–0.98 0.66–1.76 0.27–4.97

**p < 0.01; *p < 0.05.

(refer group) and 312 had passed the initial screening test (control group); 432 children from the refer group and 284 children from the control group underwent the diagnostic test. The age and gender distributions of the children are listed in Table 1. The follow-up diagnostic assessment compliance rate was 66.8% and 91.0% for the refer and control groups, respectively. Hearing loss was confirmed in 131 children from the refer group and in 31 children from the control group. Among these 162 children, 15 (9.26%) had sensorineural loss and 147 (90.47%) had conductive hearing loss.

Sensitivity and specificity of the automated screening test The sensitivity and specificity of the automated hearing screening test were calculated for the different age groups with the pure-tone audiometry test results as the gold standard. Both the sensitivity and specificity improved as the age of the subjects increased, as shown in Table 3. The sensitivity increased from 0.33 (95% CI: 0.09 – 0.69) in the youngest group to 0.95 (95% CI: 0.74 – 1.00) in the oldest group. The specificity increased from 0.15 (95% CI: 0.08 – 0.25) in the youngest group to 1.00 (95% CI: 0.88 – 1.00) in the oldest group.

Risk factors for hearing loss Of the 959 preschool children who completed the diagnostic audiological assessment, 104 hearing loss cases (46 boys and 58 girls) and 201 controls (107 boys and 94 girls) were included in a univariate case-control study that evaluated risk factors. The odds ratios (OR) of the

studied factors are listed in Table 4. Significantly elevated OR were correlated with universal newborn hearing screening test results (OR ¼ 28.15, p < 0.01), parental suspicion of hearing loss (OR ¼ 10.10, p < 0.05), and attendance at preschool before the age of 5 (OR ¼ 0.51, p < 0.05).

Discussion In this study, an automated hearing screening system for preschool children was evaluated. A previous study evaluating the system in school children (6 – 10 years old)11 found the sensitivity and specificity of the system to be 0.63 and 0.82, respectively. There are several possible reasons for the improvement in sensitivity and specificity in the present study. In the previous study, screening was only performed once, and all of the children who failed the test the first time were placed in the refer group. It was found that some of these children failed the test because they were unfamiliar with the test system and needed more practice. Thus in the present study, an immediate rescreen for those who failed the first attempt was mandatory, and only those who failed the rescreen were placed in the refer group. This procedure may help to decrease the number of false positive cases in the testing. However, the test may become boring if too much practice is performed. Although the attention problem was not observed in this study, children’s attention may be maintained by adding a wider variety of reinforcers in the future version of the automated hearing screening system.

Downloaded from msc.sagepub.com at The University of Hong Kong Libraries on May 7, 2015

74

Journal of Medical Screening 21(2)

Another possible reason for the higher sensitivity and specificity in the present study was the better control of ambient noise level in the test environment. The ambient noise level ranged from 45 to 65 dBA in the previous study, whereas the range of ambient noise level measured in the present test environment was 40 to 51 dBA. As shown in the previous study, even when noise-cancelling headphones were used with the automated test system, the test results were still significantly affected by ambient noise levels. Thus, it is not surprising that a lower ambient noise level would result in fewer false positives. Most of the children were able to complete the automated tests by themselves in this study. The incompletion rate dropped from 2.39% in the 3 years–3 years 11 months age group to 0% in the 6 years–6 years 11 months age group. The use of conventional pure-tone screening in the preschool populations has been questioned, as some research has found that the incompletion rate of the test could reach 45% in the 3-year-old age group and 7% in the 4-year-old age group.13 The incompletion rates for the automated system were much lower than those reported for the conventional pure-tone screening. There was a significant age effect on the failure rates, suggesting that the automated screening system is more suitable for children aged 5 or older. The sensitivity and specificity of the automated screening test were low in the 3 year–3 years 11 months and 4 year–4 years 11 months group, but high in the two older groups. This further suggests that the automated hearing screening test was a reliable and valid test for children as young as 5 years old. Noncompliance for follow-up care has been considered as the greatest challenge that affects the success of any mass-screening programme.14 The follow-up diagnostic assessment compliance rate was only 66.8% for the refer group. This is relatively low, especially when compared with the compliance rate of 91.0% for the control group. The follow-up diagnostic assessment was provided free of charge for both subject groups. It is interesting that parents of the control group were more willing to bring their children to obtain the diagnostic assessment than the refer group. It is possible that some parents do not think their child has a significant hearing problem, or some parents may fear the possibility of their child needing amplification and the long-standing stigma of hearing aid use.14 If these are the reasons, public education should be strengthened to enhance awareness of the importance of early identification of and intervention in hearing loss. Universal newborn hearing screening has been implemented in Shanghai since 2002. Subjects with congenital hearing loss may have been identified well before this study. It is possible that parents of children with known sensorineural hearing loss did not think they need the diagnostic assessment. It may also explain why so few cases of sensorineural hearing loss, but a relatively high proportion of conductive hearing loss was identified in this study. All of the conductive hearing loss cases identified were caused by otitis media with effusion (OME). The prevalence of OME was 2.36% (147/6231) in this study

but the figure may have been underestimated as our screening system does not test the 500 Hz which is an important frequency for assessing the auditory impact of middle ear disease.15 Risk factors for hearing loss were also investigated in this study. The newborn hearing screening test results were the most significant risk factor for hearing loss, followed by parental suspicion of hearing loss. Interestingly, none of the parents of those children who failed the newborn hearing screening test suspected that their children had hearing loss. The follow-up service that these children had received after the newborn screening was unknown. Long-term monitoring, and at the very least parental observation, may be warranted for children who failed newborn hearing screening. The automated screening test results are now stored as online data (cloud storage). Cloud data management enables systematic and accurate follow-up even for large-scale screening programmes. Cloud storage has been proven to be a reliable and stable method for handling this study’s thousands of participants. Compared with the conventional pure tone screening test, the automated test is more engaging and is better able to maintain children’s attention. A facilitator with minimal training, rather than an audiologist, can monitor the automated test. The automatic screening system is thus more feasible for use in places where professional support is scarce. Declaration of interest The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

Ethical considerations Research ethics approval was granted by the Medical Ethics Committee of the Xinhua Hospital, Shanghai Jiaotong University for the study (No. XHEC-C-2012-006).

Funding This project was supported by grants from the Health Ministry Special Fund, China (grant number 201202005) and the 12th Five-Year National Key Technologies R&D Program (2012BAI12B01).

References 1. Busa J, Harrison J, Chappell J, et al. Year 2007 position statement: Principles and guidelines for early hearing detection and intervention programs. Pediatrics 2007;120(4): 898–921. 2. American Speech-Language-Hearing Association. Guidelines for audiologic screening, http://www.asha.org/policy/GL199700199.htm (1997, accessed May 12, 2012). 3. Hammond PD, Gold MS, Wigg NR, et al. Preschool hearing screening: Evaluation of a parental questionnaire. J Paediatr Child Health 1997;33(6): 528–530. 4. Harlor AD Jr, Bower C, Walker RD, et al. Clinical report hearing assessment in infants and children: Recommendations beyond neonatal screening. Pediatrics 2009;124(4): 1252–1263.

Downloaded from msc.sagepub.com at The University of Hong Kong Libraries on May 7, 2015

Kam et al.

75

5. Krueger WWO, Ferguson L. A comparison of screening methods in school-aged children. Otolaryngol Head Neck Surg 2002;127(6): 516–519. 6. Liao WH, Lien CF, Young ST. The hearing scale test for hearing screening of school-age children. Int J Pediatr Otorhinolaryngol 2010;74(7): 760–764. 7. Lyons A, Kei J, Driscoll C. Distortion product otoacoustic emissions in children at school entry: A comparison with pure-tone screening and tympanometry results. J Am Acad Audiol 2004;15(10): 702–715. 8. Sideris I, Glattke TJ. A comparison of two methods of hearing screening in the preschool population. J Commun Disord 2006;39(6): 391–401. 9. Halloran DR, Hardin JM, Wall TC. Validity of pure-tone hearing screening at well-child visits. Arch Pediatr Adolesc Med 2009;163(2): 158–163. 10. Yin L, Bottrell C, Clarke N, et al. Otoacoustic emissions: A valid, efficient first-line hearing screen for preschool children: Research article. J Sch Health 2009;79(4): 147–152.

11. Kam ACS, Gao H, Li LKC, et al. Automated hearing screening for children: A pilot study in China. Int J Audiol 2013;52(12): 855–860. 12. American National Standards Institute. America national standard specification for audiometers. ANSI S3.6. New York: Acoustical Society of America, 2004. 13. Halloran DR, Wall TC, Evans HH, et al. Hearing screening at well-child visits. Arch Pediatr Adolesc Med 2005;159(10): 949–955. 14. Allen RL, Everett D, Elangovan S. Preschool hearing screening: Pass/refer rates for children enrolled in a Head Start program in Eastern North Carolina. Am J Audiol 2004;13:29–38. 15. Silman S, Silverman CA, Arick DS. Pure-tone assessment and screening of children with middle-ear effusion. J Am Acad Audiol 1994;5:173–182.

Downloaded from msc.sagepub.com at The University of Hong Kong Libraries on May 7, 2015

Automated hearing screening for preschool children.

To establish the reliability and validity of an automated hearing screening test system for preschoolers and to investigate the risk factors for heari...
76KB Sizes 3 Downloads 2 Views