525677 research-article2014

MSJ0010.1177/1352458514525677Multiple Sclerosis JournalLamers and Feys

MULTIPLE SCLEROSIS MSJ JOURNAL

Topical Review

Assessing upper limb function in multiple sclerosis

Multiple Sclerosis Journal 2014, Vol. 20(7) 775­–784 © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav DOI: 10.1177/1352458514525677 msj.sagepub.com

Ilse Lamers and Peter Feys

Abstract The need to fully assess upper limb function in multiple sclerosis (MS) has become increasingly clear with recent studies revealing a high prevalence of upper limb dysfunction in persons with MS leading to increased dependency and reduced quality of life. It is important that clinicians and researchers use tailored outcome measures to systematically describe upper limb (dys)function and evaluate potential deterioration or improvement on treatment. This topical review provides a comprehensive summary of currently used upper limb outcome measures in MS, classified according to the levels of the International Classification of Functioning (ICF). The clinical utility, strengths, weaknesses and psychometric properties of common upper limb outcome measures are discussed. Based on this information, recommendations for selecting appropriate upper limb outcome measures are given. The current shortcomings in assessment which need to be addressed are identified. Keywords Multiple sclerosis, upper extremity, outcome assessment (health care), psychometric properties Received: 31 January 2014; accepted: 4 February 2014

Introduction The importance of addressing upper limb function in multiple sclerosis (MS) is increasingly recognised, with recent studies revealing a high percentage of persons with MS (PwMS) reporting upper limb dysfunction, even in the early stages of the disease. In a study by Holper et al., more than 50% of 205 PwMS (mean Expanded Disability Status Scale (EDSS)=3.5, SD=2.0) reported impairment or restriction related to upper limb function,1 with the highest prevalence of upper limb disability found in the group with progressive disease. These high percentages of selfreported impairments and restrictions were confirmed by Johansson et al. in 219 PwMS (EDSS range=0–9.5) using an objective measure of manual dexterity, the Nine-Hole Peg Test (NHPT); 76% of the patients included had disability in their manual dexterity.2 Kierkegaard et al. found manual dexterity (measured by the NHPT) to be an important predictor of overall activity and participation within the community (as assessed by the Katz Activities of Daily Living (ADL) index and Frenchay Activity Index).3 Upper limb dysfunction in MS contributes to reduced ability to perform ADL, resulting in decreased independence and quality of life.4 Therefore, it is important that clinicians and researchers pay attention to the progression of upper

limb dysfunction in PwMS and consider management strategies. In order to evaluate both disease progression and the effect of management strategies on the functioning of the upper limbs, tailored outcome measures are needed. In the 1990s, a task force appointed by the National Multiple Sclerosis Society’s Advisory Committee on Clinical Trials of New Agents in Multiple Sclerosis developed a new outcome measure in response to the shortcomings of the EDSS.5,6 This new outcome measure, the Multiple Sclerosis Functional Composite (MSFC), incorporated measures addressing three important domains: ambulation, cognition and upper limb function. Since then, the NHPT has been the most frequently used outcome measure to assess upper limb dysfunction in clinical trials.7 REVAL – Rehabilitation Research Institute, BIOMED – Biomedical Research Institute, Faculty of Medicine and Life Sciences, Hasselt University, Belgium. Corresponding author: Ilse Lamers, REVAL – BIOMED, Hasselt University, Martelarenlaan 42, Hasselt, 3500, Belgium. Email: [email protected]

Downloaded from msj.sagepub.com at FLORIDA INTERNATIONAL UNIV on May 24, 2015

776

Multiple Sclerosis Journal 20(7)

Figure 1.  Upper limb outcome measures classified according to International Classification of Functioning (ICF) levels.

TEMPA: Test d’Evaluation des Membres Supérieurs de Personnes Âgées; DASH: Disabilities of the Arm, Shoulder, and Hand Scale; MAM-36: Manual Ability Measure-36; MAL: Motor Activity Log.

However, the NHPT assesses only the ability to perform fine dextrous manual movements and does not evaluate other important aspects of upper limb function, such as inhand manipulation of objects, movements in the proximal part of the upper limb (e.g. reaching, lifting), gross manual dexterity (e.g. grasping and handling of large objects) or complex coordinated bimanual tasks (e.g. eating with knife and fork) which are crucial to perform ADL. In this wider context, one must consider lesser known outcome measures that are so far only infrequently used, mainly restricted to MS rehabilitation studies. Most of these outcome measures were originally developed to assess upper limb dysfunction in other neurological diseases (e.g. stroke). There are several reviews published describing their clinical utility and psychometric properties in the setting of other diseases;8–11 however, it has to be verified whether these outcome measures are also appropriate to evaluate upper limb function in PwMS.

Upper limb assessment according to International Classification of Functioning (ICF) levels The ICF is a well-established framework that can be used to classify outcome measures according to three levels: ‘body functions and structures’, ‘activity’ and ‘participation’.

Figure 1 provides an overview of previously used upper limb outcome measures in PwMS classified according to the ICF levels.7 Outcome measures on the ‘participation’ level assess restrictions an individual may have in involvement in life situations.12 The Katz Personal and Instrumental ADL index, the Frenchay Activities Index and the Functional Independence Measure are frequently used outcome measures assessing restriction on ‘activity’ and ‘participation’ level.2,3,13–15 These outcome measures are all, however, strongly influenced by the person’s walking ability, their ability to independently perform a transfer and cognitive function. There is no outcome measure available which investigates only the impact of upper limb dysfunction on participation. Outcome measures on ‘activity’ level are applied to understand the problems PwMS have in performing ADL related to the upper limb. Within this level, capacity and performances measures are differentiated. Measures of capacity, by definition, assess the maximal ability to execute a task or an action in a given domain at a given moment in a standardised environment while measures of performance assess the person’s habitual performance of a task or action in his or her normal environment.12 The most established upper limb capacity measure in MS is the NHPT.7 However, other outcome measures such as the Box and Block Test (BBT) and the Action Research

Downloaded from msj.sagepub.com at FLORIDA INTERNATIONAL UNIV on May 24, 2015

Unilateral gross manual dexterity

Unilateral ability to handle objects.

Unilateral fine manual dexterity

Jebsen Taylor Hand Function Test (JTT)23

Nine-Hole Peg Test (NHPT)5

Unilateral ability to handle objects and to perform gross upper limb movements

Box and Blox test (BBT)21,22

Action Research Arm test (ARAT)19,36

What is measured?

Table 1.  Description of upper limb capacity measures.

Nineteen unilateral test items divided into four subtests: grasp, grip, pinch and gross movements. Each item is scored using a four-point ordinal scale (0–3 points). Maximum score is 57. Persons are asked to transfers as many blocks as possible from one to another box, one block at a time. The amount of blocks transferred in one minute is recorded. Seven unilateral ADLlike tasks need to be performed as quickly as possible. The time needed to perform a task is recorded (time limit set at 120 seconds). Persons are asked to place and remove nine pegs, one at a time and as quickly as possible (time limit set at 300 seconds). Time needed to perform the task is recorded. Pegs per second can be calculated to avoid floor effects.

Description of the test

Easy and quick to conduct. Normative values are available.

Easy and quick to conduct. Normative values are available. Evaluates different grasp, grip and pinch functions.

Easy and relatively quick to conduct. Appropriate for patients with marked upper limb dysfunction. Requires both proximal and distal motor ability. Evaluates different grasp, grip and pinch functions. Easy and quick to conduct. Normative values are available. Performance requires proximal and distal upper limb movements.

Strengths

Requires that a person is able to pick up a peg and manipulate it in one hand.

Requires that a person is able to manipulate objects.

Requires that a person is able to pick up a block.

Ceiling effect in persons with less impaired upper limb function.18,19 Ordinal scale.

Weaknesses

Downloaded from msj.sagepub.com at FLORIDA INTERNATIONAL UNIV on May 24, 2015

(Continued)

Maximum five minutes for each arm

c. Fifteen minutes for both arms

c. Two minutes for each arm

c. Ten minutes for each arm

Time to complete

Lamers and Feys 777

Downloaded from msj.sagepub.com at FLORIDA INTERNATIONAL UNIV on May 24, 2015

Upper limb motor ability through timed and functional tasks.

Wolf Motor Function Test (WMFT)26

Persons are asked the place as many pegs (with the dominant, non-dominant hand and bilaterally) or assemblies as possible in 30 seconds or one minute, respectively. From all tests the number of pins or assemblies are recorded. Nine ADL-like tasks (five bilateral and four unilateral) are scored according to three criteria: the speed of execution, function rating (four-point ordinal scale; 0–3 points) and a task analysis which helps to identify and rate difficulty. Seventeen items (unilateral and bilateral) are timed (WFMT-time) and scored with the Functional Ability Score (WFMT-FAS; three-point ordinal scale). The first six items assess the ability to perform analytical movement in the different joints of the upper limb, while the other items are functional tasks. The time limit for each item is 120 seconds.

Description of the test

Appropriate for persons with different levels of upper limb dysfunction. Evaluates different grasp, grip and pinch functions.

The test provides a unilateral and bilateral score. Requires both proximal and distal motor ability. Normative values are available. Evaluates different grasp, grip and pinch functions.

Easy and quick to conduct. Norm values are available. The test provides a unilateral and bilateral score.

Strengths

Takes longer to conduct and more time is needed for the instructor to get familiar with the test and the instructions compared to the other tests.

Longer than other test to conduct. Requires that a person is able to manipulate objects.

Requires that a person is able to pick up and manipulate a peg.

Weaknesses

c. Thirty minutes for each arm

c. Fifteen minutes for each arm

c. Five minutes for both arms

Time to complete

ADL: activities of daily living; TEMPA: Test d’Evaluation des Membres Supérieurs de Personnes Âgées. Test instructions, score forms and equipment specifications of the different outcome measures can be obtained through the references or online resources (e.g. www.rehabmeasures.org, www.strokengine.ca, www.cebp.nl).

Unilateral and bilateral ability to perform ADL tasks requiring fine and gross manual dexterity

Unilateral and bilateral fine manual dexterity

What is measured?

TEMPA25

Purdue Pegboard Test24

Table 1. (Continued)

778 Multiple Sclerosis Journal 20(7)

779

Lamers and Feys Arm Test (ARAT) are also frequently used in rehabilitation trials.7,16 Table 1 provides information about the clinical utility, strengths and weaknesses of seven common upper limb capacity outcome measures. It is apparent from this table that all capacity outcome measures include test items requiring grasp and/or manipulation function, which may be difficult to perform for PwMS with severe hand and upper limb dysfunction, possibly leading to a floor effect if the object cannot be grasped properly. The NHPT, BBT and Purdue Pegboard mainly assess the ability to repeatedly perform one particular type of grasp function as quickly as possible, while the ARAT, Jebsen Taylor Hand Function Test (JTT), Test d’Evaluation des Membres Supérieurs de Personnes Âgées (TEMPA) and Wolf Motor Function Test (WMFT) assess the ability to perform different ADL-like tasks requiring manipulation or transportation of standardized small and large objects using different grasp, grip and pinch functions. The score of the Purdue Pegboard Test is expressed in seconds while the score of the NHPT can be expressed in seconds or pegs per second to avoid floor effects in persons with more severe hand impairment. Items of the JTT are scored using only a time score while in both the TEMPA and WMFT, an ordinal functional rating score along with a time score is given for each test item. The ARAT uses an ordinal scale, which takes the time needed to perform the task into account when scoring the test items. Besides a total score of the ARAT, the subscores for the different grip functions and gross movements can also be reported separately.17 A drawback of outcome measures applying an ordinal scale is the risk of ceiling effects in persons with only mild impairment given that the difficulty level of included test items may vary (e.g. ARAT18,19). Furthermore, it is notable that only three out of the seven capacity outcome measures include one or more items which are performed bilaterally. All our measures assessing upper limb capacity are thus, perhaps, of limited value given the finding of Kilbreath and Heard,20 who reported that healthy subjects mainly use both upper limbs together to perform tasks in their daily life. Performance measures are relatively recently introduced in MS and can be either subjective (perceived performance) or objective (actual performance). The ABILHAND,27–29 Disabilities of the Arm, Shoulder, and Hand Scale (DASH),30 Manual Ability Measure-36 (MAM-36)31,32 and Motor Activity Log (MAL)18,33,34 are used to assess perceived performance, while accelerometers are used to assess actual performance. Description, strengths and weaknesses of the perceived performances measures are provided in Table 2. All questionnaires include rating on unilateral and bilateral tasks, except the ABILHAND, which includes only bilateral tasks. The ABILHAND, DASH and MAM-36 assess the perceived ease/difficulty when performing ADL regardless of which upper limb is used, while the MAL assesses the ‘amount of upper limb use’ and ‘quality of upper limb use’ during ADL. For both

the ABILHAND and MAM-36, a conversion table is available to obtain a Rasch-derived score, which is regarded as superior to a summed score or calculated scores as used in the MAL and DASH.35 The use of accelerometers to objectively assess upper limb performance in daily life, similar to step count for the lower limbs, is attractive but currently still has technical challenges (e.g. filtering out general body movements or wheelchair acceleration) dictating the need to interpret the results with caution. However, a reasonable correlation with upper limb capacity measures has been shown while differences between dominant and non-dominant hand can be captured.18 Outcome measures on the ‘activity’ level provide information on the problems that PwMS are facing during their ADL. However, to optimize treatment strategies, one should also include outcome measures identifying the contributing impairments at the ‘body functions and structures’ level. Outcome measures on this level assess the physiological functions of anatomical parts of the body.12 A large number of different outcome measures are available to assess impairments such as ataxia, tremor, muscle weakness, decreased active range of motion, sensory dysfunction and spasticity. The most frequently used outcome measure on this level is hand grip strength, followed by ataxia and tremor rating scales, Motricity Index to assess general upper limb strength, the Modified Ashworth scale to evaluate spasticity, Semmes Weinstein Monofilaments and tuning fork to assess sensory function.7 The majority of these outcome measures are ordinal rating scales performed by physicians, as such relying on the competence and consistency of the rater, which makes them less suitable for intervention trials.

Psychometric properties of measures at the ‘activity’ level Knowledge of psychometric properties such as validity, reliability and responsiveness is crucial to select the most appropriate outcome measure for a given purpose. In this review, we focus on the psychometric properties of capacity measures on ‘activity’ level, which are presented in Table 3. The results of these psychometric studies should be interpreted with caution as these values are influenced by sample size, upper limb disability level of the included study sample and the statistics that have been performed. In general, the psychometric properties are all insufficiently documented for most of these outcome measures, except for the NHPT, which has been found to be reliable and valid. For all other measures, although only few psychometric studies have been reported, the available values are encouraging. Remarkably, reliability in PwMS has not yet been investigated for the TEMPA and WMFT while most of the outcome measures have been validated against the NHPT as a gold standard. Responsiveness was rarely investigated for any outcome measure and, when done, was studied only in relation to the longitudinal deterioration

Downloaded from msj.sagepub.com at FLORIDA INTERNATIONAL UNIV on May 24, 2015

Downloaded from msj.sagepub.com at FLORIDA INTERNATIONAL UNIV on May 24, 2015

The symptoms of upper limb dysfunction and the ability to perform unilateral and bilateral activities.

Perceived ease or difficulty that a person may experience when performing unilateral and bilateral ADL tasks.

How much (quantity) and how well (quality) persons use their upper limb in their daily life.

DASH38

MAM-3632

MAL39

During a semi-structured interview, the persons are asked to rate 36 unilateral and bilateral ADL tasks using a four-point scale. The score of the different tasks are summed up and transformed using a Rasch-derived conversion table. During a semi-structured interview, persons are asked to score their performance on the included ADL tasks using a six-point ordinal scale (0–5 points) reflecting the ‘amount of use’ and the ‘quality of use’. The sum score results in a ‘use score’ (0–10).

During a semi-structured interview, persons are asked to rate 23 bilateral ADL tasks using a three-point ordinal scale. The score of the different tasks are summed up and transformed using a Rasch-derived conversion table. Persons are asked to rate 30 tasks related to daily life using a five-point ordinal scale (1–5) reflecting the ease or difficulty perceived while performing the task in the last week. A formula is giving to calculate the total score.

Description of the test

The MAL includes unilateral and bilateral ADL tasks. The MAL scores reflect the quantity and quality of upper limb performance on daily life, which provides more information than scores of reported ease or difficulty.

Easy and quick to conduct. A conversion table is available to obtain a Rasch-derived MAM36 score. The MAM-36 is available in different languages.

Easy and quick to conduct. The DASH is available in different languages.

Easy and quick to conduct. Easy to obtain a Rasch-derived ABILHAND score. The ABILHAND is available in different languages.

Strengths

No Rasch-derived scores available.

Some of the included tasks require, beside a good upper limb function, a good balance or walking ability. Low psychometric properties were found for the DASH.30

The ABILHAND only includes more complex bilateral tasks.

Weaknesses

c. Twenty minutes

c. Ten minutes

c. Fifteen minutes

c. Ten minutes

Time

ADL: activities of daily living; DASH: Disabilities of the Arm, Shoulder, and Hand Scale; MAM-36: Manual Ability Measure-36; MAL: Motor Activity Log. Test instructions and score forms of the different questionnaires can be obtained through the references or online resources (e.g. www.rehabmeasures.org, www.strokengine.ca, www.cebp.nl, www.dash.iwh.on.ca, www.rehab-scales.org).

Perceived ease or difficulty that a person may experience when performing bilateral ADL tasks in the last three months.

ABILHAND37

What is measured?

Table 2.  Description of upper limb perceived performance measures.

780 Multiple Sclerosis Journal 20(7)

Downloaded from msj.sagepub.com at FLORIDA INTERNATIONAL UNIV on May 24, 2015

ICC = 0.98 (0.95–0.99)46 ICC =  0.96–0.98 (0.91–0.99)47

ICC = 0.93 (0.84–0.96)47

ICC = 0.92–0.9650

ICC = 0.85–0.9050

ICC  =  0.88 (0.69–0.96)49

ρ  =  0.86–0.9248

r  =  0.9844

ICC = 0.87–0.91 (0.72– 0.96), SEM = 3.27–3.54, CV = 4.441 ICC = 0.96, ρ  =  0.9719 r  =  0.9544

ICC = 0.93–0.94 (0.73– 0.99), SEM = 2.43–2.45, CV = 4.2–4.441 ICC = 0.99, ρ  =  0.9919

ICC = 0.98 (0.96–0.99)46

ICC = 0.97, ρ  =  0.9719

Test-retest reliability

ICC   =   0.99, ρ  =  0.9919

Intra-rater reliability

NHPT: r  =  –0.52a29 ABILHAND: r  =  0.49a29 JTT: ρ  =  –0.56b to –0.73b45, ρ  =  0.72b–0.87b45 NHPT: ρ  =  –0.79b to –0.90b45, ρ  =  0.81b–0.90b45

JTT: ρ  =  0.83b–0.95b45, r  =  0.86a–0.88a44 Purdue Pegboard: r  =  –0.52a29 TEMPA functional rating: ρ  =  –079b to –0.90b45 TEMPA speed: ρ  =  0.81b–0.90b45 ABILHAND: r  =  –0.37a29 MAL: ρ  =  –0.56a to –0.79a18 BBT: r  =  0.80a29

MIC =  –0.06 to –0.1440   MDC =  8.1143 MIC =  –3.48 to –5.2343

MAL: ρ  =  0.28–0.70a18 MAL: ρ  =  0.30–0.48a33 ARAT: ρ  =  0.95b19 NHPT: r  =  –0.41a29, r  =  –0.70b42 Purdue Pegboard: r  =  0.80a29 ABILHAND: r  =  0.48a29 NHPT: ρ  =  0.83b–0.95b45, r  =  0.86a–0.88a44 TEMPA functional rating: ρ  =  –0.56b to –0.73b45 TEMPA speed: ρ  =  0.72b–0.87b45 BBT: r  =  –0.41a29, r  =  –0.70b42



     

       

   

MIC =  0.30–0.5140

  SRC =  2.82–5.3240



   

SRC =  –1.61 to –5.2740

Responsiveness

BBT: ρ  =  0.95b19

Validity

TEMPA: Test d’Evaluation des Membres Supérieurs de Personnes Âgées; ICC: intraclass correlation coefficient; (95% confidence interval); ρ: Spearman correlation coefficient; r: Pearson correlation coefficient; SEM: standard error of measurement; CV: coefficient of variation; MIC: minimally important change; MDC: minimal detectable change; SRC: smallest real change. ap < 0.05. bSignificance not reported.



      Purdue Pegboard test     TEMPA

   

  Nine-Hole Peg Test (NHPT)  

  Jebsen Taylor Hand Function Test (JTT)  

Action Research Arm test (ARAT)     Box and Blox test (BBT)

Inter-rater reliability

Table 3.  Psychometric properties of upper limb capacity measures.

Lamers and Feys 781

782

Multiple Sclerosis Journal 20(7)

caused by disease progression. For the NHPT, a minimally important change between 0.30 and 0.51 seconds has been described,40 with other studies suggesting a 20% threshold for clinical meaningful change.51–54 Data on responsiveness have been reported for the ARAT40 and BBT,43 while responsiveness of the JTT, Purdue Pegboard Test, TEMPA and WMFT has not yet been described. Psychometric properties of the perceived performance measures were mostly investigated using Rasch measurement methods.27,30,32 The ABILHAND27 and MAM-3632 appeared to be reliable and valid in MS, in contrast to the low psychometric properties that were found for the DASH30 and the lack of data for the MAL. Responsiveness has not yet been investigated for any of the perceived performance measures in MS. There are no psychometric data available yet for accelerometry as an objective performance measure in MS. Correlation coefficients between capacity and perceived performance measures were variable indicating that both types of measures assess different aspects of upper limb function. This finding suggests the need to use both types of outcome measures to adequately assess the upper limb in MS.

Selecting appropriate upper limb outcome measures The selection of appropriate upper limb outcome measures depends on the intended purpose, which may range from fast screening for abnormalities to a more detailed documentation of upper limb dysfunction and evaluation of management strategies. The NHPT seems acceptable as a fast screening tool to discriminate between normal and impaired manual dexterity based on normative data. In this regard, Kierkegaard et al. proposed a cut-off value of the NHPT which may be used to identify PwMS at risk of limitation in activity or restriction of participation.3 However, the proposed cut-off value (0.5 pegs/seconds or 18 seconds) seems very strict: healthy subjects in different age categories are not able to perform the NHPT in less than 18 seconds.55 Alternatively, one could also opt to use the BBT or Purdue Pegboard Test as fast screening tools. In contrast to the NHPT, the BBT requires a less precise grip and more involvement of the proximal upper limb muscles while the Purdue Pegboard Test may detect more subtle deficits, given the smaller pegs and bimanual movements. However, abnormal scores on these fast screening tools are not perfectly related to the disability found with other more comprehensive capacity measures (Table 3). By using more comprehensive capacity measures such as the ARAT, TEMPA, WMFT or JTT, one is able to better understand which components of the upper limb movement are affected (e.g. type of grasp, grip or pinch, presence of proximal or distal muscle weakness, spasticity or incoordination). Conducting these measures may also guide and facilitate individual management strategies to improve upper limb-related ADL. To

select the right capacity measures, one must take into account both the clinical utility of the outcome measures and also the severity of upper limb dysfunction anticipated. However, only two studies have reported on the ceiling effect of capacity measures, and comparative data on floor and ceiling effects in MS are needed to draw firm conclusions.18, 19 Recently, more attention has been paid to patientreported outcome measures.35 These perceived performance measures give more information about the difficulties PwMS experience when performing specific upper limb tasks in their home situation, the latter being considered as the ultimate goal of treatment. Recent studies18,33 have indicated that although scores on capacity measures are (almost) normal, PwMS still report upper limb disability affecting their ADL performance. Therefore, we recommend using the ABILHAND or MAM-36, depending on the upper limb severity level of the patient sample, to assess the ease/difficulty when performing ADL related to the upper limb. The MAL and accelerometry can be used to assess the use of the upper limbs in daily life. Albeit attractive as a concept, the psychometric properties of these need further investigation and the technical challenges for accelerometers need to be resolved.

Gaps in the upper limb assessment We must acknowledge that, despite the large number of available assessment tools, current upper limb assessment in MS still has limitations. Studies18,31,48,56 have indicated that the relationship between capacity measures on ‘activity’ level and impairments on ‘body function and structures’ level such as muscle weakness, spasticity, impaired coordination and sensory function, are inconsistent. With current knowledge, the use of technology could provide more detailed information on other impairments which are rarely addressed such as incoordination, decreased force control, movement variability and selectivity. In this regard, instrumented assessment tools such as finger tapping,57 virtual peg boards,58,59 and instrumented objects60 assessing more complex and integrated motor function are promising tools which can give more information about the presence of impairments on ‘body functions and structures’ level while performing a functional task on ‘activity’ level. By providing more objective and quantitative data, these assessment tools may be able to be more sensitive for the early detection of upper limb dysfunction and for changes due to deterioration/ intervention. Furthermore, they also may facilitate the evolution of rehabilitation content and strategies. However, more research regarding the benefits of these instrumented assessment tools and their psychometric properties is needed. A major limitation of the current outcome measures of ‘activity’ level is that they often assess only the ability to perform a relatively short task while PwMS sometimes report increased fatigability interfering with the prolonged execution of functional activities such as typing or eating.

Downloaded from msj.sagepub.com at FLORIDA INTERNATIONAL UNIV on May 24, 2015

783

Lamers and Feys Static and dynamic motor fatigue indexes, calculated based on a sustained and repeated hand grip contractions, were originally developed by Schwid et al.61 but are rarely applied. However, the discriminative power of both indexes needs further investigation while the relation with prolonged daily life activities remains to be determined.

Conclusion In this review, we have highlighted firstly the lack of studies investigating psychometric properties of upper limb outcome measures in MS, especially regarding the responsiveness of outcome measures after an intervention. Secondly, as described in other neurological pathologies8,10 and obvious from this review, there is no single outcome measure available that covers the entire range of upper limb functionality and is applicable across different upper limb disability levels. Outcome measures on the different ICF levels are essential to fully understand upper limb dysfunction and improve (the evaluation of) management strategies. The correct use and interpretation of existing scales, and the development of improved instruments, should be a priority for those looking to use quantitative measures of upper limb function in their clinical practice or in the design of clinical trials. Conflict of interest None declared.

Funding Ilse Lamers is supported by a PhD fellowship from the Research Council of Hasselt University (BOF-grant).

References 1. Holper L, Coenen M, Weise A, et al. Characterization of functioning in multiple sclerosis using the ICF. J Neurol 2010; 257: 103–113. 2. Johansson S, Ytterberg C, Claesson IM, et al. High concurrent presence of disability in multiple sclerosis. Associations with perceived health. J Neurol 2007; 254: 767–773. 3. Kierkegaard M, Einarsson U, Gottberg K, et al. The relationship between walking, manual dexterity, cognition and activity/participation in persons with multiple sclerosis. Mult Scler 2012; 18: 639–646. 4. Yozbatiran N, Baskurt F, Baskurt Z, et al. Motor assessment of upper extremity function and its relation with fatigue, cognitive function and quality of life in multiple sclerosis patients. J Neurol Sci 2006; 246: 117–122. 5. Cutter GR, Baier ML, Rudick RA, et al. Development of a multiple sclerosis functional composite as a clinical trial outcome measure. Brain 1999; 122 ( Pt 5): 871–882. 6. Amato MP and Ponziani G. Quantification of impairment in MS: Discussion of the scales in use. Mult Scler 1999; 5: 216–219. 7. Lamers I, Kelchtermans S, Baert I, et al. Upper limb assessment in multiple sclerosis: A systematic review of outcome measures and their psychometric properties. Arch Phys Med Rehabil 2014; (in press).

8. Ashford S, Slade M, Malaprade F, et al. Evaluation of functional outcome measures for the hemiparetic upper limb: A systematic review. J Rehabil Med 2008; 40: 787–795. 9. Connell LA and Tyson SF. Clinical reality of measuring upper-limb ability in neurologic conditions: A systematic review. Arch Phys Med Rehabil 2012; 93: 221–228. 10. Lang CE, Bland MD, Bailey RR, et al. Assessment of upper extremity impairment, function, and activity after stroke: Foundations for clinical decision making. J Hand Ther 2013; 26: 104–114. 11. Lemmens RJ, Timmermans AA, Janssen-Potten YJ, et al. Valid and reliable instruments for arm-hand assessment at ICF activity level in persons with hemiplegia: A systematic review. BMC Neurol 2012; 12: 21. 12. World Health Organization. Programmes and projects. Classifications. http://www.who.int/classifications/icf/en/ (2013, accessed 10 November 2013). 13. Einarsson U, Gottberg K, Fredrikson S, et al. Activities of daily living and social activities in people with multiple sclerosis in Stockholm County. Clin Rehabil 2006; 20: 543–551. 14. Mansson E and Lexell J. Performance of activities of daily living in multiple sclerosis. Disabil Rehabil 2004; 26: 576–585. 15. Ytterberg C, Johansson S, Andersson M, et al. Variations in functioning and disability in multiple sclerosis. A two-year prospective study. J Neurol 2008; 255: 967–973. 16. Spooren AI, Timmermans AA and Seelen HA. Motor training programs of arm and hand in patients with MS according to different levels of the ICF: A systematic review. BMC Neurol 2012; 12: 49. 17. Carpinella I, Cattaneo D, Bertoni R, et al. Robot training of upper limb in multiple sclerosis: Comparing protocols with or without manipulative task components. IEEE Trans Neural Syst Rehabil Eng 2012; 20: 351–360. 18. Lamers I, Kerkhofs L, Raats J, et al. Perceived and actual arm performance in multiple sclerosis: Relationship with clinical tests according to hand dominance. Mult Scler 2013; 19: 1341–1348. 19. Platz T, Pinkowski C, van Wijck F, et al. Reliability and validity of arm function assessment with standardized guidelines for the Fugl-Meyer Test, Action Research Arm Test and Box and Block Test: A multicentre study. Clin Rehabil 2005; 19: 404–411. 20. Kilbreath SL and Heard RC. Frequency of hand use in healthy older persons. Aust J Physiother 2005; 51: 119–122. 21. Platz T, Pinkowski C, van Wijck F, et al. ARM—Arm Rehabilitation Measurements: Manual for performance and scoring of the Fugl-Meyer test, Action Research Arm Test and the Box-and-Block test. Deutscher WissenschaftsVerlag (DWV), Baden-Baden (Germany) 2005. 22. Mathiowetz V, Volland G, Kashman N, et al. Adult norms for the Box and Block Test of manual dexterity. Am J Occup Ther 1985; 39: 386–391. 23. Jebsen RH, Taylor N, Trieschmann RB, et al. An objective and standardized test of hand function. Arch Phys Med Rehabil 1969; 50: 311–319. 24. Tiffin J and Asher EJ. The Purdue pegboard; norms and studies of reliability and validity. J Appl Psychol 1948; 32: 234–247. 25. Desrosiers J, Hérbert R, Dutil E, et al. Development and reliability of an upper extremity function test for the elderly: The TEMPA. Can J Occup Ther 1993; 60: 9–16.

Downloaded from msj.sagepub.com at FLORIDA INTERNATIONAL UNIV on May 24, 2015

784

Multiple Sclerosis Journal 20(7)

26. Wolf SL, Catlin PA, Ellis M, et al. Assessing Wolf motor function test as outcome measure for research in patients after stroke. Stroke 2001; 32: 1635–1639. 27. Barrett L, Cano S, Zajicek J, et al. Can the ABILHAND handle manual ability in MS? Mult Scler 2012. 28. Hermens H, Huijgen B, Giacomozzi C, et al. Clinical assessment of the HELLODOC tele-rehabilitation service. Ann Ist Super Sanita 2008; 44: 154–163. 29. Simone A, Rota V, Tesio L, et al. Generic ABILHAND questionnaire can measure manual ability across a variety of motor impairments. Int J Rehabil Res 2011; 34: 131–140. 30. Cano SJ, Barrett LE, Zajicek JP, et al. Beyond the reach of traditional analyses: Using Rasch to evaluate the DASH in people with multiple sclerosis. Mult Scler 2011; 17: 214–222. 31. Chen CC, Kasven N, Karpatkin HI, et al. Hand strength and perceived manual ability among patients with multiple sclerosis. Arch Phys Med Rehabil 2007; 88: 794–797. 32. Chen CC and Bode RK. Psychometric validation of the Manual Ability Measure-36 (MAM-36) in patients with neurologic and musculoskeletal disorders. Arch Phys Med Rehabil 2010; 91: 414–420. 33. Lamers I, Timmermans AA, Kerkhofs L, et al. Self-reported use of the upper limbs related to clinical tests in persons with multiple sclerosis. Disabil Rehabil 2013; 35: 2016–2020. 34. Mark VW, Taub E, Bashir K, et al. Constraint-induced movement therapy can improve hemiparetic progressive multiple sclerosis. Preliminary findings. Mult Scler 2008; 14: 992–994. 35. Mayo NE, Hum S and Kuspinar A. Methods and measures: What’s new for MS? Mult Scler 2013; 19: 709–713. 36. Lyle RC. A performance test for assessment of upper limb function in physical rehabilitation treatment and research. Int J Rehabil Res 1981; 4: 483–492. 37. Penta M, Thonnard JL and Tesio L. ABILHAND: A Raschbuilt measure of manual ability. Arch Phys Med Rehabil 1998; 79: 1038–1042. 38. Hudak PL, Amadio PC and Bombardier C. Development of an upper extremity outcome measure: The DASH (disabilities of the arm, shoulder and hand) [corrected]. The Upper Extremity Collaborative Group (UECG). Am J Ind Med 1996; 29: 602–608. 39. Taub E, Miller NE, Novack TA, et al. Technique to improve chronic motor deficit after stroke. Arch Phys Med Rehabil 1993; 74: 347–354. 40. de Groot V, Beckerman H, Uitdehaag BM, et al. The usefulness of evaluative outcome measures in patients with multiple sclerosis. Brain 2006; 129: 2648–2659. 41. Paltamaa J, West H, Sarasoja T, et al. Reliability of physical functioning measures in ambulatory subjects with MS. Physiother Res Int 2005; 10: 93–109. 42. Goodkin DE, Hertsgaard D and Seminary J. Upper extremity function in multiple sclerosis: Improving assessment sensitivity with box-and-block and nine-hole peg tests. Arch Phys Med Rehabil 1988; 69: 850–854. 43. Paltamaa J, Sarasoja T, Leskinen E, et al. Measuring deterioration in international classification of functioning domains of people with multiple sclerosis who are ambulatory. Phys Ther 2008; 88: 176–190. 44. Bovend’Eerdt TJ, Dawes H, Johansen-Berg H, et al. Evaluation of the Modified Jebsen Test of Hand Function

and the University of Maryland Arm Questionnaire for Stroke. Clin Rehabil 2004; 18: 195–202. 45. Feys P, Duportail M, Kos D, et al. Validity of the TEMPA for the measurement of upper limb function in multiple sclerosis. Clin Rehabil 2002; 16: 166–173. 46. Rosti-Otajarvi E, Hamalainen P, Koivisto K, et al. The reliability of the MSFC and its components. Acta Neurol Scand 2008; 117: 421–427. 47. Solari A, Radice D, Manneschi L, et al. The multiple sclerosis functional composite: Different practice effects in the three test components. J Neurol Sci 2005; 228: 71–74. 48. Erasmus LP, Sarno S, Albrecht H, et al. Measurement of ataxic symptoms with a graphic tablet: Standard values in controls and validity in multiple sclerosis patients. J Neurosci Methods 2001; 108: 25–37. 49. Rasova K, Martinkova P, Vyskotova J, et al. Assessment set for evaluation of clinical outcomes in multiple sclerosis: Psychometric properties. Patient Relat Outcome Meas 2012; 3: 59–70. 50. Gallus J and Mathiowetz V. Test-retest reliability of the Purdue Pegboard for persons with multiple sclerosis. Am J Occup Ther 2003; 57: 108–111. 51. Bosma LV, Kragt JJ, Brieva L, et al. Progression on the Multiple Sclerosis Functional Composite in multiple sclerosis: What is the optimal cut-off for the three components? Mult Scler 2010; 16: 862–867. 52. Hoogervorst EL, Kalkers NF, Cutter GR, et al. The patient’s perception of a (reliable) change in the Multiple Sclerosis Functional Composite. Mult Scler 2004; 10: 55–60. 53. Kragt JJ, van der Linden FA, Nielsen JM, et al. Clinical impact of 20% worsening on Timed 25-Foot Walk and 9-Hole Peg Test in multiple sclerosis. Mult Scler 2006; 12: 594–598. 54. Schwid SR, Goodman AD, McDermott MP, et al. Quantitative functional measures in MS: What is a reliable change? Neurology 2002; 58: 1294–1296. 55. Oxford GK, Vogel KA, Le V, et al. Adult norms for a commercially available Nine Hole Peg Test for finger dexterity. Am J Occup Ther 2003; 57: 570–573. 56. Guclu-Gunduz A, Citaker S, Nazliel B, et al. Upper extremity function and its relation with hand sensation and upper extremity strength in patients with multiple sclerosis. NeuroRehabilitation 2012; 30: 369–374. 57. Bonzano L, Sormani MP, Tacchino A, et al. Quantitative assessment of finger motor impairment in multiple sclerosis. PLoS One 2013; 8: e65225. 58. Lambercy O, Fluet MC, Lamers I, et al. Assessment of upper limb motor function in patients with multiple sclerosis using the Virtual Peg Insertion Test: A pilot study. IEEE Int Conf Rehabil Robot 2013; 2013: 1–6. 59. Design and development of a haptic peg-board exercise for the rehabilitation of people with multiple sclerosis. IEEE 10th International Conference on Rehabilitation Robotics. Noordwijk, The Netherlands, 7 June–15 June 2007. 60. Iyengar V, Santos MJ, Ko M, et al. Grip force control in individuals with multiple sclerosis. Neurorehabil Neural Repair 2009; 23: 855–861. 61. Schwid SR, Thornton CA, Pandya S, et al. Quantitative assessment of motor fatigue and strength in MS. Neurology 1999; 53: 743–750.

Downloaded from msj.sagepub.com at FLORIDA INTERNATIONAL UNIV on May 24, 2015

Assessing upper limb function in multiple sclerosis.

The need to fully assess upper limb function in multiple sclerosis (MS) has become increasingly clear with recent studies revealing a high prevalence ...
386KB Sizes 6 Downloads 4 Views