Life Sciences, Vol. 48, pp. 1529-1535 Printed in the U.S.A.

Pergamon Press

ANGIOTENSIN CARBOXYPEPTIDASE ACTIVITY IN URINE FROM NORMAL SUBJECTS AND PATIENTS WITH K]DNEY DAMAGE James J. Miller*, David G. Changaris, and Robert S. Levy Departments of Biochemistry and Neurology and the Laboratory of Biological Psychiatry, University of Louisville School of Medicine, Louisville, KY 40292 (Received in final form February ii, 1991)

Summary Angiotensin carboxypeptidase (ACP) activity has been detected in urine samples from normal subjects and patients with hypertension and diabetes by determining the enzyme's ability to convert angiotensin I to des-Leu angiotensin I. Gel filtration chromatography of a concentrated urine sample indicated that about equal amounts of the enzyme exist as 100 kDa and 500 kDa molecular weight forms, respectively. This ACP activity co-eluted with activity that cleaved histidine from des-Leu angiotensin I to form angiotensin II and activity that cleaved tyrosine from benzyloxycarbonyl-glutamyl-tyrosine (ZGT). These results suggest that the urinary ACP activity is due to cathepsin A as we have reported previously for the porcine kidney enzyme. Analysis of sequential urine samples from a single individual over a 6-day period revealed as much as a 6-fold fluctuation in creaUnine-normalized ACP activity. Of five male healthy adult subjects, the creatininenormalized urinary ACP activity ranged from 1.7 to 3.7 mU/mL with a mean of 2.8 mU/mL. However, five male patients with renovascular hypertension had elevated levels of ACP activity with a mean of 11.6 mU/mL. Of five male patients with diabetic nephropathy, all had elevated ACP activity levels with a mean of 21.0 mU/mL. It is concluded that ACP activity in the urine is due to cathepsin A probably derived from kidney tissue, and that the release is increased in patients with kidney damage. We suggest that urinary ACP activity should be evaluated further for a possible relationship to renal hypertension and as a potentially early marker for diabetic nephropathy. We have been studying alternate pathways for the production of angiotensin II (A II) in the kidney that do not require the participation of angiotensin converting enzyme (ACE) (t). Recently, we have reported on the angiotensin carboxypepUdase (ACP) activity of porcine kidney cathepsin A by which the enzyme generates A II from angiotensin I (A I) by two sequential C-terminal cleavages (Fig. 1) (2). It was of interest, then, to determine whether this ACP activity of cathepsin A was detectable in human urine and to learn to what extent the activity of this lysosomal enzyme might increase in urine in those patients who have experienced tissue damage due to the onset of kidney disease. A preliminary report of some of the following data has been presented (3). * Fellow of the Glenmore Foundation. Reprint requests to Robert S. Levy, Department of Biochemistry, University of Louisville School of Medicine, Louisville, KY 40292 0024-3205/91 $3.00 +.00 Copyright (c) 1991 Pergamon Press plc

1530

Anglotensln Carboxypeptldase

in Urine

Vol. 48, No. 16, 1991

Asp---Arg-VaI-Tyr-Ile-His-Pro-Pt'~-His-Leu Angiotensin I

ACE

A S l o - A r g - V a l - Tyr - I l e - H i s - P r o - P h e - H i s des-Leu Angioter~lin I H

His Asp---,~g-Val- Tyr - Ile-His-I~'o-Vl"~

Angiotensin II

Fig. 1 Conversion of angiotensin I to angiotensln II by angiotensin converting enzyme (ACE) and angiotensin carboxypeptidase (ACP). Materials and Methods Materials Angiotensin I and Creatinine Coiorimetric Kit #555-A were obtained from Sigma Chemical Company, St. Louis, MO. Sephadex G-200 was obtained from Pharmacia Fine Chemicals, Piscataway, NJ. Samples Random urine samples were obtained from five male healthy adult subjects. The samples were chilled immediately and assayed for ACP activity on the same day. The refrigerated samples also were assayed for creatinine, sodium, and potassium within one week of collection. One volunteer collected random urine samples for a period of six days. Each of these was assayed for ACP activity and creatinine. For molecular weight determination the first 910 mL (approximating a 24 hr collection) of these latter samples was pooled and concentrated about 100-fold by ultrafiltration (Amicon PM-30; no activity was present in the effluent). The protein then was precipitated with 80% ammonium sulfate, resuspended in 0.1 M NaOAc, 0.1 M sucrose, 0.1 M KCI, 1 mM EDTA, pH 5.2, and dialyzed extensively against the same buffer. The molecular weight of the ACP in this concentrated sample was determined by gel filtration chromatography. Urine samples from diabetic and non-diabetic kidney patients were obtained from the Kidney Disease Program of the Department of Medicine. Hiqh Pressure Liquid Chromatography (HPLC) A Varian model 5020 high pressure liquid chromatograph equipped with a Micromeritics 725 Autosampler; a Varian UV-50 variable wavelength detector set at 210 nm; and a Vydac C18 reversed phase column (218TP104; 10 I~, 25 x 0.46 cm) were employed for HPLC analysis. The voltage output from the detector was converted to the digital form using the Nelson Analytical Chromatography Software Model 2600 in conjunction with the Nelson Analytical Interface Model 761.

Vol. 48, No. 16, 1991

Angiotensln Carboxypeptidase in Urine

1531

Enzyme Assays ACP activity was determined by measuring the conversion of A I to des-Leu anglotensin I (dL-A I). The reaction mixture contained 200 pL of buffer (0.1 M NaOAc, 0.5 M sucrose, 0.4 M KCI, 1 mM EDTA, pH 5.8) and 25 pL of 6.87 mM A I (0.687 mM in the assay mixture). After prewarming the assay mixture to 37°C, 25 pL of urine was added and incubated for 90 min. The reaction was terminated by the addition of 500 pL of 250 mM phosphoric acid. The resulting dLA I formed was measured by reversed phase HPLC on the C18 column. The mobile phase consisted of 50 mM sodium phosphate, pH 4.0, and acetonitrile (AcN) and was pumped at one mL/min. The gradient was started at 83% aqueous, and the AcN was increased by 2%/min for 7.5 min. Detection was by absorbance at 210 nm. Peak areas were compared against those for dL-A I standards. A typical HPLC assay is shown in Fig. 2. For assays of fractions from Sephadex G-200 chromatography, 10 I=L aliquots of each fraction were incubated with 250 i~L of 68.7 pM A I or 61.1 I~M dL-A I in the above buffer for 60 min or with 250 I~L of 3 mM benzyloxycarbonyl-glutamyl-tyrosine (ZGT - cathepsin A substrata) in the same buffer. The products, dL-A I, A II or benzyloxycarbonyl-glutamic acid (ZG), were quantitated by comparison of peak areas with those of standards. Activity was expressed as milliunits (mU) per mL where one unit equals one micromole of product per minute. Unless otherwise indicated, activity is normalized by dividing by the creatinine concentration in g/L. Molecular Wei.qht Determination Sephadex G-200 was equilibrated with 0.1 M NaOAc, 0.1 M NaCI, 0.1 M sucrose, 1 mM EDTA, pH 5.2, and packed into a column (63 x 2.6 cm; 334 mL). Ten mL of the concentrated urine (see above) was applied to the column, and 5 mL fractions were collected. Fractions were assayed for cathepsin A using ZGT as substrata and for ACP activity using both A I and dL-A I as substrates. Protein in the fractions was estimated by absorbance at 280 nm. The molecular weight of the enzyme was estimated by comparison of its elution volume from this column with the elution volumes of five proteins of known molecular weight: thyroglobulin, 670 kDa; immunoglobulin G, 158 kDa; bovine serum albumin, 67 kDa; ovalbumin, 44 kDa; and myogiobin, 17 kDa. Creatinine Determination Creatinine (g/L) was measured by a modification ofthe normal phase HPLC method of Patel and George (4). Ten I~L of urine or creatinine standard was diluted with 250 pL of water and 500 I~L of AcN was added. These mixtures then were centrifuged at 13,000 x g for 5 min. A 10 pL aliquot was injected onto a Varian silica column (SI-5; 5 I~, 30 x 0.4 cm). The mobile phase, 10/150/840 parts by volume of ammonium hydroxide, methanol, and AcN, was pumped at 2.5 mL/min. The effluent was monitored at 210 nm, CreaUnine had a retention time of 5.0 min and appeared to be well-resolved from other compounds. CreaUninein five urine samples determined by this method and by the Kodak Ektachem 400 Analyzer two slide method compared favorably (least squares regression: slope, 1.012; y-intercept, -0.0204; correlation coefficient, 0.9986). The Sigma Chemical Co. Creatinine I~t based on the Jaffa method as modified by Heineg~,rd and Tiderstr0m (5) was used for all patient samples. Other Assays Sodium and potassium were assayed on a Kodak Ektachem 400 Analyzer.

1532

Anglotensin Carboxypeptldase in Urine

Vol. 48, No. 16, 1991

Results Sequential urine samples from one normal subject over a six-day period were assayed for ACP activity and creatinine. A typical HPLC tracing is shown in Fig. 2. Creatinine-normalized ACP activity varied from 1.0to 6.1 (mean 2.9) mU/mL (Fig. 3). No clear diurnal variation was apparent; however, activity did tend to be higher in the afternoon and evening. These data indicated that urine normally contains detectable ACP activity. 200 180

0 ~

140

0

® 120

(3

dL-AI

100

0

All

AI

I

I

I

I

I

I

I

I

I

I

l

I

I

1

2

3

4

5

6

7

8

9

10

11

12

13

Retention

Time

14

(min)

Fig. 2 A HPLC tracing of an aliquot of reaction mixture after incubation of urine with A I as described in the Methods section. The detector wavelength was set at 210 nm.

7

+u" 3

Angiotensin carboxypeptidase activity in urine from normal subjects and patients with kidney damage.

Angiotensin carboxypeptidase (ACP) activity has been detected in urine samples from normal subjects and patients with hypertension and diabetes by det...
368KB Sizes 0 Downloads 0 Views