A technique to splint and verify the accuracy of implant impression copings with light-polymerizing acrylic resin Vygandas Rutkunas, DDS, PhDa and Jevgenija Ignatovic, DDSb Vilnius University, Institute of Odontology, Vilnius, Lithuania Transferring the implant position from the mouth to the definitive cast is one of the most critical steps in implant prosthodontics. To achieve a passive fit of the prosthesis, an accurate implant impression is crucial because discrepancies can induce both biologic and technical complications. Analysis of available research data suggests that a direct (pick-up) impression technique with splinted copings is the technique of choice, particularly for multiple implants. However, the traditional method of splinting the copings with autopolymerizing acrylic resin is a technique-sensitive and time- consuming procedure. This report describes a straightforward method of splinting impression copings with light-polymerizing acrylic resin, with minimal amount of autopolymerizing acrylic resin. The method also can be used to verify splinting accuracy. (J Prosthet Dent 2014;111:254-256)

Dental implants, because they do not have a periodontal ligament, are not able to compensate for even minor misfits of the superstructure.1 Therefore, recording a correct 3-dimensional orientation rather than surface detail is necessary to avoid biologic and technical complications.2 Many factors are involved in transferring the implant position from the mouth to the cast, including the implant connection type and impression coping design, the number of implants and angulation, the impression technique, and the impression material. Whereas the influence of different impression materials appears to be less critical, impression techniques are considered as a major factor that influences impression accuracy.3,4 Implant impression copings can be repositioned into the impression material after impression making with a closed tray (indirect, transfer) technique or can be transferred with impression material with an open tray (direct, pick-up) technique. Both techniques and their modifications are used to achieve implant impression accuracy. To improve the stability of the impression coping, splinting techniques have been adopted. Although there are conflicting data on the effects of different impression

1 Direct impression copings placed on mandibular posterior implants.

2 Strip of light-polymerizing acrylic resin cut from Individo Lux (Voco GmbH) custom tray material.

a

Associate Professor, Faculty of Medicine, Division of Prosthodontics. Resident, Faculty of Medicine, Division of Prosthodontics.

b

The Journal of Prosthetic Dentistry

Rutkunas and Ignatovic

March 2014 techniques and splinting, a systematic review has revealed that more studies reported higher accuracy with direct techniques when splinting was used.4 Different materials have been suggested for coping splinting, including acrylic resin, plaster, polyvinyl siloxane, and polyether.5,6 The application of an autopolymerizing acrylic resin to a scaffold of dental floss is a common technique. However, this is time-consuming and technique-sensitive procedure when multiple implants are to be restored in the posterior region because unpolymerized resin can be displaced by the cheek or tongue, and the splint can be detached from the coping. Autopolymerized acrylic resins shrink during polymerization and generate strains.7 To compensate for acrylic resin shrinkage, the splint can be sectioned and reconnected with a small amount of resin.8 This article describes a method to splint impression copings with a lightpolymerizing custom tray acrylic resin. The mechanical properties of lightpolymerized resins have been rated superior to autopolymerized resins.9 The advantages of this technique include an easy and fast way to connect impression copings (especially for multiple implant-supported prostheses), better patient acceptance, the uniform coverage of impression copings with an adequate thickness of resin, the uniform thickness of the splint, and the avoidance of intraoral resin monomer. Also, the consistency of lightpolymerizing resin does not require the use of dental floss. The verification of splinting accuracy can be done before impression making as well as after cast fabrication to evaluate the accuracy of the cast.10 The disadvantages include possible problems of access for the lightpolymerization unit, interference with the impression tray due to the thicker layer of resin surrounding the impression coping, inadequate adaptation of the light-polymerizing resin to the coping, incomplete polymerization of the material, and an inability to fully avoid the use of autopolymerized acrylic resin.

Rutkunas and Ignatovic

255

3 Light-polymerizing acrylic resin strip adapted to impression copings.

4 Polymerization of splint.

5 Splint was cut and rejoined with autopolymerizing acrylic resin.

TECHNIQUE 1. Remove the interim abutments and place the direct implant impression copings (EZ Plus; Megagen Co) (Fig. 1). Make a radiograph to confirm the

complete seating of the impression coping. 2. Cut an appropriate 5-mm-wide strip of acrylic resin from the lightpolymerizing custom tray material (Individo Lux; Voco GmbH) (Fig. 2).

256

Volume 111 Issue 3

6 Splinted copings were removed to ensure good attachment of material to copings and to verify passive fit.

7 Definitive impression made with high and medium viscosity polyvinyl siloxane material. Wrap the resin strip around the copings and shape with a modeling spatula to ensure good adaptation of the material and provide space beneath the splint for impression material (Fig. 3). Lightpolymerize for 60 seconds on each side with a 1200 mW/cm2 light-intensity unit (Elipar Free Light 2; 3M/ESPE) (Fig. 4). 3. After the resin has polymerized, cut the splint with a small diameter rotary instrument (D203; Hager & Meisinger GmbH) to compensate for the shrinkage and rejoin with autopolymerizing acrylic resin (Pattern Resin; GC) (Fig. 5). Confirm splinting by removing, examining, and reattaching the copings (Fig. 6). Perform the Sheffield 1-screw test to verify the accuracy of the splint.11

4. Adjust the custom tray and make a definitive impression with polyvinyl siloxane impression material (Take 1 Advanced HB Tray and medium viscosity material; Kerr Corp) (Fig. 7). The Sheffield test can be performed on the definitive cast with the same or an additional set of splinted copings to evaluate the accuracy of the definitive cast.12

REFERENCES 1. Cordaro L, Ercoli C, Rossini C, Torsello F, Feng C. Retrospective evaluation of complete-arch fixed partial dentures connecting teeth and implant abutments in patients with normal and reduced periodontal support. J Prosthet Dent 2005;94:313-20.

The Journal of Prosthetic Dentistry

2. Vigolo P, Fonzi F, Majzoub Z, Cordioli G. An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent 2004;92:470-6. 3. Wostmann B, Rehmann P, Balkenhol M. Influence of impression technique and material on the accuracy of multiple implant impressions. Int J Prosthodont 2008;21: 299-301. 4. Lee H, So JS, Hochstedler JL, Ercoli C. The accuracy of implant impressions: a systematic review. J Prosthet Dent 2008;100: 285-91. 5. Hariharan R, Shankar C, Rajan M, Baig MR, Azhagarasan NS. Evaluation of accuracy of multiple dental implant impressions using various splinting materials. Int J Oral Maxillofac Implants 2010;25:38-44. 6. Ma J, Rubenstein JE. Complete arch implant impression technique. J Prosthet Dent 2012;107:405-10. 7. Cerqueira NM, Ozcan M, Gonçalves M, da Rocha DM, Vasconcellos DK, Bottino MA, et al. A strain gauge analysis of microstrain induced by various splinting methods and acrylic resin types for implant impressions. Int J Oral Maxillofac Implants 2012;27: 341-5. 8. Filho HG, Mazaro JV, Vedovatto E, Assuncao WG, dos Santos PH. Accuracy of impression techniques for implants. Part 2-comparison of splinting techniques. J Prosthodont 2009;18:172-6. 9. Khan SB, Geerts G. Determining the dimensional stability, fracture toughness and flexural strength of light-cured acrylic resin custom tray material. Eur J Prosthodont Restor Dent 2009;17:67-72. 10. Ercoli C, Geminiani A, Feng C, Lee H. The influence of verification jig on framework fit for nonsegmented fixed implantsupported complete denture. Clin Implant Dent Relat Res 2012;14(suppl 1): e188-95. 11. McDonnell T, Houston F, Byrne D, Gorman C, Claffey NJ. The effect of time lapse on the accuracy of two acrylic resins used to assemble an implant framework for soldering. Prosthet Dent 2004;91:538-40. 12. Sadid-Zadeh R, O’Neal SJ, Liu PR, AponteWesson R. A technique for verifying implant analog positions in the definitive cast. J Prosthet Dent 2013;109:192-7. Corresponding author: Dr Vygandas Rutkunas no. 217 Zalgirio Street 115 08217 Vilnius LITHUANIA E-mail: [email protected] Copyright ª 2014 by the Editorial Council for The Journal of Prosthetic Dentistry.

Rutkunas and Ignatovic

A technique to splint and verify the accuracy of implant impression copings with light-polymerizing acrylic resin.

Transferring the implant position from the mouth to the definitive cast is one of the most critical steps in implant prosthodontics. To achieve a pass...
1MB Sizes 2 Downloads 0 Views